HCS01.1E-W0009-A-02-A-CC-EC-CN-NN-NN-FW
HCS IndraDrive Controllers
The HCS01.1E-W0009-A-02-A-CC-EC-CN-NN-NN-FW from Bosch Rexroth Indramat features internal air cooling with integrated blower and a peak current of 9 A. As part of the HCS IndraDrive Controllers this compact converter supports a mains voltage of 3×110230 V B110% and has an IP20 protection class.
It offers SERCOS III master cross communication and a CANopen interface with up to 127 nodes adhering to EN 50325-4. The unit measures 215D7196D750 mm and requires a 15-minute cooldown after shutdown.
Technical Specifications
Communication Interface
SERCOS III master (cross communication)
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
CANopen
Safety Interface
Not equipped
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Device Peak Current
9 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
How does SERCOS III coordination help HCS01.1E-W0009-A-02-A-CC-EC-CN-NN-NN-FW?
SERCOS III allows it to maintain synchronized multi-axis communication, minimizing cycle lag for precise, deterministic operation in motion-heavy tasks.
Why is CANopen integration valuable in HCS01.1E-W0009-A-02-A-CC-EC-CN-NN-NN-FW?
CANopen enables effortless linking with existing field devices, sensors and actuators and maintains compatibility in mixed or legacy automation networks.
How does low mains voltage aid HCS01.1E-W0009-A-02-A-CC-EC-CN-NN-NN-FW retrofits?
Lower voltage allows it to fit into older cabinet infrastructures, reducing power reconfiguration while maintaining stable drive synchronization.
What encoders work with HCS01.1E-W0009-A-02-A-CC-EC-CN-NN-NN-FW?
It supports IndraDyn Hiperface and EnDat encoders for accurate motion control, diagnostics and high-fidelity positioning feedback.
How should IP20 influence HCS01.1E-W0009-A-02-A-CC-EC-CN-NN-NN-FW placement?
Use it in protected enclosures away from moisture or debris, ensuring smooth blower operation and circuit safety.
Common Misspellings
HCS011EW0009A02ACCECCNNNNNFW
HCS01 1E W0009 A 02 A CC EC CN NN NN FW
hcs01.1e-w0008-a-03-b-et-ec-cn-l3-nn-fw
HCS1.1E-W0009-A-02-A-CC-EC-CN-NN-NN-FW
Internal Product Review
The Bosch Rexroth Indramat's HCS01.1E-W0009-A-02-A-CC-EC-CN-NN-NN-FW merges SERCOS III control with CANopen flexibility in a space-saving format. Designed for compact retrofits, its blower-cooled body supports smaller power setups without sacrificing coordination accuracy.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0009-A-02-A-CC-EC-CN-NN-NN-FW.
Want to 