HCS01.1E-W0009-A-02-A-CC-EC-ET-L3-NN-FW
HCS IndraDrive Controllers
The Bosch Rexroth Indramat HCS01.1E-W0009-A-02-A-CC-EC-ET-L3-NN-FW drive controller from the HCS IndraDrive Controllers series is a robust and compact solution for precise motion control. It features a SERCOS III master (cross communication) interface and supports encoder feedback via IndraDyn Hiperface/EnDat 2.1/2.2 and a secondary MultiEthernet interface. Designed with an ADVANCED control section, it operates on a mains voltage of 3 x AC 110...230 V ±10% and delivers a device peak current of 9 A. The internal blower provides efficient air cooling, and the unit meets IP20 protection standards. Safety is ensured by an integrated STO (Safe Torque Off) interface, while firmware must be ordered as a separate sub-position. Compatible with the HCS01 line series and paired with the Control Section Design 'ADVANCED', this converter requires no additional design features.
Technical Specifications
Communication Interface
SERCOS III master (cross communication)
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
MultiEthernet
Safety Interface
STO (Safe Torque Off)
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Device Peak Current
9 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
What redundancy of HCS01.1E-W0009-A-02-A-CC-EC-ET-L3-NN-FW does dual encoder support provide?
Two encoder channels enable redundancy or multi-sensor fusion for improved fault tolerance and diagnostics.
How should STO wiring be validated by HCS01.1E-W0009-A-02-A-CC-EC-ET-L3-NN-FW?
Validate STO inputs for correct wiring, response time and integration with the machine safety controller under test.
What commissioning steps of HCS01.1E-W0009-A-02-A-CC-EC-ET-L3-NN-FW verify network integration?
Validate SERCOS timing and packet integrity, test MultiEthernet telemetry and confirm encoder synchronization under load.
How does blower cooling affect panel layout of HCS01.1E-W0009-A-02-A-CC-EC-ET-L3-NN-FW?
Blower requires intake/exhaust clearances; arrange components to avoid recirculation from neighboring heat sources.
Which encoder protocols of HCS01.1E-W0009-A-02-A-CC-EC-ET-L3-NN-FW are supported and why?
Supports IndraDyn Hiperface and EnDat for high-resolution feedback and diagnostics to aid tight control loops.
Common Misspellings
HCS011EW0009A02ACCECETL3NNFW
HCS01 1E W0009 A 02 A CC EC ET L3 NN FW
hcs01.1e-w0008-a-03-b-et-ec-ec-l3-nn-fw
HCS1.1E-W0009-A-02-A-CC-EC-ET-L3-NN-FW
Internal Product Review
Indramat's HCS01.1E-W0009-A-02-A-CC-EC-ET-L3-NN-FW controller supports and also includes STO safety and blower-based cooling that help maintain efficient operation in compact cabinets, making it a favourite among users.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0009-A-02-A-CC-EC-ET-L3-NN-FW.
Want to 




