HCS01.1E-W0009-A-02-A-CC-EC-NN-L3-NN-FW, Bosch Rexroth Indramat, HCS IndraDrive Controllers deliver a highly compact drive controller engineered for precision motion tasks. This HCS Drive Controller features a robust 3 x AC 110...230 V ±10% mains input and supports up to 9 A device peak current, making it ideal for dynamic single- and multi-axis applications. The unit’s integrated blower enables air, internal (through integrated blower) cooling without external fans, ensuring consistent thermal management across varying loads. Its sleek profile and modular architecture simplify integration into existing control cabinets while maintaining industrial-grade performance.



Equipped with a native SERCOS III master (cross communication) interface, the controller facilitates real-time data exchange and multi-node synchronisation across complex motion networks. Encoder feedback is handled via the dedicated Encoder IndraDyn Hiperface/EnDat 2.1/2.2 port, while the optional second interface remains available for future expansions. The built-in STO (Safe Torque Off) safety interface meets modern functional safety requirements, instantly disabling drive outputs in emergency conditions. Classified as IP20, the housing protects sensitive electronics from solid ingress, and the device meets Category C3 EMC standards under IEC 61800-3. Firmware is ordered separately per the Firmware Order Note, and the controller pairs with Control Section Design type ADVANCED as specified in the Pairing Note.



Designed for seamless commissioning, the HCS01.1E-W0009-A-02-A-CC-EC-NN-L3-NN-FW’s front-panel interface and straightforward power supply unit configuration speed up setup on the plant floor. Its compatible design version 1 ensures firmware compatibility and future upgrade paths without hardware changes. The combination of compact form factor, integrated blower cooling, and comprehensive safety functions delivers reliable operation in packaging, handling, and machine tool installations, reducing downtime and maintenance complexity.

Technical Specifications

Communication Interface
SERCOS III master (cross communication)

Pairing Note
Paired with Control Section Design 'ADVANCED' (A)

Control Section Design Type
ADVANCED

Cooling Method
Air, internal (through integrated blower)

IP Rating
IP20

Design Version
1

Other Design Features
None

Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2

Interface 2 Type
Not equipped

Safety Interface
STO (Safe Torque Off)

Line Series
HCS01

Mains Voltage
3 x AC 110...230 V ±10%

Device Peak Current
9 A

Power Supply Unit
Infeeding / Feeded

Product Type
HCS Drive Controller

What is the significance of the 3 x AC 110...230 V ±10% mains voltage input for the HCS01.1E-W0009-A-02-A-CC-EC-NN-L3-NN-FW?

This wide input range ensures that the HCS01.1E-W0009-A-02-A-CC-EC-NN-L3-NN-FW is adaptable to varying power conditions, improving its compatibility across different industrial environments. It supports consistent performance despite fluctuations in mains voltage.

Why does the HCS01.1E-W0009-A-02-A-CC-EC-NN-L3-NN-FW use an integrated blower for cooling?

The integrated blower provides internal cooling, eliminating the need for external fans. This design ensures consistent thermal management, which enhances reliability and reduces the potential for overheating during operation.

What benefits does the SERCOS III master interface offer in the HCS01.1E-W0009-A-02-A-CC-EC-NN-L3-NN-FW?

The SERCOS III master interface enables real-time data exchange and multi-node synchronization, ensuring precise coordination in complex motion networks. It helps improve system performance and reduces the risk of communication delays in dynamic applications.

Why is the HCS01.1E-W0009-A-02-A-CC-EC-NN-L3-NN-FW classified under Category C3 EMC standards?

The C3 EMC classification ensures that the HCS01.1E-W0009-A-02-A-CC-EC-NN-L3-NN-FW meets industrial electromagnetic compatibility requirements, minimizing interference with other equipment. This helps ensure stable and reliable operation in industrial environments.

What does the "Infeeding / Feeded" power supply unit configuration mean for the HCS01.1E-W0009-A-02-A-CC-EC-NN-L3-NN-FW?

The "Infeeding / Feeded" configuration allows the unit to both supply and receive power from the connected system. This ensures flexibility in power distribution, making the controller adaptable to different setup scenarios.

HCS011EW0009A02ACCECNNL3NNFW

HCS01 1E W0009 A 02 A CC EC NN L3 NN FW

hcs01.1e-w0008-a-03-b-et-ec-ec-s4-nn-fw

HCS1.1E-W0009-A-02-A-CC-EC-NN-L3-NN-FW

Internal Product Review

Bosch Rexroth produces the HCS01.1E-W0009-A-02-A-CC-EC-NN-L3-NN-FW controller which is engineered for dynamic motion control. It operates with a 3-phase AC 110-230 V input and delivers a 9 A peak current. This drive controller is perfect for multi-axis systems, featuring a SERCOS III master interface for real-time synchronization. Its internal blower cooling and safety interface (STO) make it suitable for industries like packaging, machine tools, and automation, ensuring consistent operation and enhanced safety with minimal maintenance.

Warranty

1-year-warranty
Indramat USA 1 Year Warranty

Repair

product repair We offer a repair service for the HCS01.1E-W0009-A-02-A-CC-EC-NN-L3-NN-FW.