HCS01.1E-W0013-A-02-B-ET-EC-EP-L4-NN-FW
HCS IndraDrive Controllers
Technical Specifications
Communication Interface
MultiEthernet
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Safety Interface
STO (Safe Torque Off) and SBC (Safe Brake Control)
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Device Peak Current
13 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
What MultiEthernet options on HCS01.1E-W0013-A-02-B-ET-EC-EP-L4-NN-FW enable controller interoperability across PLC ecosystems?
The BASIC control section supports Rexroth’s MultiEthernet stack for common industrial Ethernet protocols for easing PLC integration and fieldbus migration. It simplifies retrofits and mixed-vendor lines while preserving diagnostics and motion profiles.
How do STO and SBC in the HCS01.1E-W0013-A-02-B-ET-EC-EP-L4-NN-FW reduce risk during hazardous motion events?
It removes drive-enable for preventing torque generation, while safe brake control commands and monitors the motor brake. It shortens response chains and supports category-appropriate PL/SIL designs in machinery.
How does the 13 A device-peak capability of HCS01.1E-W0013-A-02-B-ET-EC-EP-L4-NN-FW influence axis sizing?
The 13 A peak allows short-term torque headroom for acceleration and disturbance rejection while maintaining thermal limits. It is recommended to use duty-cycle and RMS current calculations to select compliant motors and gear ratios.
Why must firmware be ordered separately for this HCS01 configuration, and how does that affect commissioning?
This catalog variant requires firmware as a separate configuration item for allowing feature set tailoring. It is recommended during commissioning to load the licensed firmware level to unlock technology functions and protocol options.
What panel-level EMC practices are recommended when supplying multiple HCS01 units from one source?
The IndraDrive Cs components are Category C3. It is important to use mains filters, shielded cabling, correct grounding and segregated routing.
Common Misspellings
HCS011EW0013A02BETECEPL4NNFW
HCS01 1E W0013 A 02 B ET EC EP L4 NN FW
hcs01.1e-w0009-a-02-b-et-ec-pb-s4-nn-fw
HCS1.1E-W0013-A-02-B-ET-EC-EP-L4-NN-FW
Internal Product Review
The Bosch Rexroth’s HCS IndraDrive controller HCS01.1E-W0013-A-02-B-ET-EC-EP-L4-NN-FW is designed for supplying an output peak current rating of 13 A. It integrates MultiEthernet and a multi-encoder front end with STO/SBC for safety. It utilizes an internal-blower unit for cooling and it comes with basic IP20 protection rating that allows its installation in controlled cabinets. It is widely used in machine tools and robotics systems.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0013-A-02-B-ET-EC-EP-L4-NN-FW.
Want to 