HCS01.1E-W0013-A-02-B-ET-EC-NN-L3-NN-FW
HCS IndraDrive Controllers
Technical Specifications
Communication Interface
MultiEthernet
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
Safety Interface
STO (Safe Torque Off)
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Device Peak Current
13 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
Why is STO (L3) on this HCS drive controller valuable in machinery safety chains?
It cuts drive torque via a safety-rated path for enabling safe stop without mechanical contactors and faster restart sequences. It simplifies achieving PL/SIL targets when paired with appropriate safety controls.
The HCS01.1E-W0013 variant lists 13 A device peak current—what use cases benefit from this rating?
Its short-term 13 A peaks help cover dynamic acceleration or cutting transients without oversizing the power section. Its typical beneficiaries are pick-and-place axes, feeders, light machine-tool secondaries and label/printing stations.
How does internal air cooling (integrated blower) in HCS01.1E-W0013-A-02-B-ET-EC-NN-L3-NN-FW affect cabinet design?
The self-ventilated path removes heat to the cabinet air, so designers must ensure adequate panel airflow and derating considerations. It does not need liquid loop for reducing plumbing and maintenance complexity.
What encoder systems can this code’s multi-encoder interface evaluate, and why does that matter?
The interface supports common formats such as HIPERFACE® and EnDat 2.1/2.2 for enabling broad motor/feedback interoperability. This flexibility eases migrations and spare-parts stocking across mixed legacy and new axes.
Does the IP20 rating of HCS01.1E-W0013 limit placement, and what mitigations are typical?
The IP20 requires installation within a protective electrical enclosure, away from conductive dust and liquid exposure. Its designers typically combines filtered panel ventilation and correct clearances to maintain thermal margins.
Common Misspellings
HCS011EW0013A02BETECNNL3NNFW
HCS01 1E W0013 A 02 B ET EC NN L3 NN FW
hcs01.1e-w0009-a-02-e-s3-ec-nn-nn-aa-fw
HCS1.1E-W0013-A-02-B-ET-EC-NN-L3-NN-FW
Internal Product Review
The Indramat’s HCS01.1E-W0013-A-02-B-ET-EC-NN-L3-NN-FW drive controller pairs a BASIC (B) control section with MultiEthernet, IP20 construction and internal air cooling. It is built for rated 3×AC 110–230 V (±10%) supply source and it supports up to 13 A of peak load. This drive includes STO functionality for safety and possess Multi-encoder Hiperface/EnDat inputs that makes it suitable for packaging, printing, machine tools and semiconductor handling applications.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0013-A-02-B-ET-EC-NN-L3-NN-FW.
Want to 