HCS01.1E-W0013-A-02-B-ET-EC-NN-L3-NN-NW
HCS IndraDrive Controllers
Technical Specifications
Communication Interface
MultiEthernet
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
Safety Interface
STO (Safe Torque Off)
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Device Peak Current
13 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
Which encoder systems can the HCS01’s multi-encoder front end evaluate, and when would you pick each?
It accepts HIPERFACE®, EnDat 2.1/2.2, SSI, TTL, sin/cos, resolver and Rexroth MSM. It is recommended to use resolvers for harsh environments and Hiperface/EnDat for high resolution and electronic nameplate benefits.
Does the integrated blower on the HCS01.1E affect cabinet thermal design or spacing rules?
Yes, the internal air cooling with performance-dependent fan control aids heat removal but still requires clearance and proper cabinet airflow per the planning manual. It is important to observe spacing, inlet paths and ambient limits to avoid derating.
What IP rating and mechanical format are specified, and what does that mean for enclosure choices?
The HCS01 power section is IP20 and compact (narrow form factor), so it must be mounted in a protected electrical cabinet with appropriate filtration and EMC layout to meet industrial environments.
What peak current class is typical for the W0013 device, and how does that influence motor pairing?
The W0013 variant sits in the ~13 A peak class within IndraDrive Cs sizing tables. It is recommended to select MS2N/MSK/MSM motors whose peak/continuous currents align with cycle demands and thermal limits.
How does the L3 STO on HCS01.1E-W0013-A-02-B-ET-EC-NN-L3-NN-NW contribute to functional safety during e-stops?
It disables the power stage to prevent torque generation for enabling a Category-compatible stop without encoder feedback. It reduces wiring complexity versus contactor-based schemes while maintaining restart-inhibit behavior.
Common Misspellings
HCS011EW0013A02BETECNNL3NNNW
HCS01 1E W0013 A 02 B ET EC NN L3 NN NW
hcs01.1e-w0009-a-02-e-s3-ec-nn-nn-nn-fw
HCS1.1E-W0013-A-02-B-ET-EC-NN-L3-NN-NW
Internal Product Review
The HCS series drive controller HCS01.1E-W0013-A-02-B-ET-EC-NN-L3-NN-NW from Bosch Rexroth Indramat blends MultiEthernet control, STO safety and internal blower cooling within an IP20 housing. Its operating range is specified as 3-phase 110–230 V AC with ~13 A peak load output. It serves in packaging, printing, assembly, machine-tool and semiconductor handling lines.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0013-A-02-B-ET-EC-NN-L3-NN-NW.
Want to 