HCS01.1E-W0013-A-02-E-S3-EC-NN-L4-NN-FW
HCS IndraDrive Controllers
The Bosch Rexroth Indramat HCS01.1E-W0013-A-02-E-S3-EC-NN-L4-NN-FW from the HCS IndraDrive Controllers series is a HCS Drive Controller designed for precision motor control in demanding industrial applications. This controller accepts a Mains Voltage of 3 x AC 110...230 V ±10% and provides a Device Peak Current of 13 A through an integrated Power Supply Unit configured as both infeeding and feeded. Communication is achieved via the robust Communication Interface of SERCOS III, ensuring deterministic real-time data exchange with minimal latency. The controller’s Line Series designation HCS01 underscores its compatibility with a wide range of Rexroth drives and encoders.
Reliability features include an Air, internal (through integrated blower) Cooling Method that maintains stable operation under high load, while the IP20 IP Rating enclosure protects internal electronics from solid particles above 12 mm. Safety is prioritized with built-in STO (Safe Torque Off) and SBC (Safe Brake Control) interfaces, enabling rapid shutdown in emergency scenarios. The unit interfaces with motor feedback via Encoder IndraDyn Hiperface/EnDat 2.1/2.2 standards (Interface 1 Type), and additional ports are left unpopulated (Interface 2 Type: Not equipped). Commissioning is simplified by the Pairing Note entry, specifying pairing with the Control Section Design ‘ECONOMY’ (E), and firmware availability is detailed under Firmware Order Note.
Compact and efficient, this converter embodies the Control Section Design Type ECONOMY approach, reducing cabinet space and energy consumption. With Design Version 1 and no extra features listed under Other Design Features, the device delivers core functionality without unnecessary complexity. Ideal for integration into IP54-protected enclosures, the HCS01.1E-W0013-A-02-E-S3-EC-NN-L4-NN-FW stands ready to drive servomotors with high precision, safety, and efficiency.
Technical Specifications
Communication Interface
SERCOS III
Pairing Note
Paired with Control Section Design 'ECONOMY' (E)
Control Section Design Type
ECONOMY
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
Safety Interface
STO (Safe Torque Off) and SBC (Safe Brake Control)
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Device Peak Current
13 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
What encoder feedbacks are supported by the “EC” multi-encoder interface and why does it matter?
The EC option accepts HIPERFACE and EnDat 2.1/2.2 (among others in the series) for enabling flexible motor/feedback pairing and lifecycle service. It simplifies retrofits and multi-vendor motor strategies without re-engineering mechanics.
How does SERCOS III on HCS01.1E-W0013-A-02-E-S3-EC-NN-L4-NN-FW improve axis coordination and cycle determinism?
ItI provides real-time, isochronous communication with microsecond-class synchronization for minimizing jitter between controller and drives. Its consistency enhances multi-axis interpolation, camming and coordinated motion in packaging, printing and handling equipment.
How do STO and SBC on product code HCS01.1E-W0013-A-02-E-S3-EC-NN-L4-NN-FW reduce external safety hardware?
The STO safely removes torque, while its SBC actuates the motor brake. It reduces separate contactors/relays and shortens response paths for emergency stops.
Why is “infeeding/feeded” PSU design useful in distributed machines using HCS01.1E-W0013-A-02-E-S3-EC-NN-L4-NN-FW?
The Infeeding/feeded topologies enable energy sharing and regulated DC-bus management across axes. Its regenerative braking energy can be reused on other drives or dissipated efficiently for improving energy utilization in cyclic motion machines.
How does the internal air-cooling (integrated blower) affect thermal design and uptime for product code HCS01.1E-W0013-A-02-E-S3-EC-NN-L4-NN-FW?
The integrated fan maintains component temperatures within specification under dynamic load for reducing derating during rapid cycles. It also simplifies panel design by avoiding external liquid loops or heat exchangers.
Common Misspellings
HCS011EW0013A02ES3ECNNL4NNFW
HCS01 1E W0013 A 02 E S3 EC NN L4 NN FW
hcs01.1e-w0013-a-02-a-cc-ec-nn-nn-nn-fw
HCS1.1E-W0013-A-02-E-S3-EC-NN-L4-NN-FW
Internal Product Review
Bosch Rexroth develops the HCS01.1E-W0013-A-02-E-S3-EC-NN-L4-NN-FW drive controller with rated 3×AC 110–230 V operations. Its SERCOS III motion networking and 13 A peak current provides reliable peak operations. The unit's ECONOMY control section pairing and EC multi-encoder support streamlines commissioning, while its STO/SBC safety eases risk reduction in automotive assembly lines.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0013-A-02-E-S3-EC-NN-L4-NN-FW.
Want to 