1-888-551-3082 | 1-919-443-0207 | sales@indramat-usa.com

HCS01.1E-W0013_A-02-B-ET-EC-NN-NN-NN-FW

HCS IndraDrive Controllers

  In-Stock, Ships 3-5 Days
Expedited Lead Times on Select Parts
1 Year Warranty Included
Free Ground Shipping
Expedited Lead Times on Select Parts
1 Year Warranty Included
Free Ground Shipping

The Bosch Rexroth Indramat HCS01.1E-W0013_A-02-B-ET-EC-NN-NN-NN-FW from the HCS IndraDrive Controllers series is a HCS Drive Controller in the HCS01 line series designed for versatile automation tasks. This controller accepts a mains voltage of 3 x AC 110...230 V 
B1�0% and delivers a device peak current of 13 A for demanding motion applications. Equipped with a native MultiEthernet communication interface and an Encoder IndraDyn Hiperface/EnDat 2.1/2.2 interface 1 type, it ensures precise feedback and seamless integration. The compact design carries an IP20 rating for panel-mounted installations, combining robustness with a small footprint.



The HCS drive controller features an air, internal (through integrated blower) cooling method that maintains optimal thermal management even under continuous load. Its power supply unit configuration supports both infeeding and feeded modes to match grid and regenerative energy requirements. Internal filters providing capacitance against housing of 2×68nF reduce electromagnetic interference and maintain compliance with industry standards. The device ships with standard control panel firmware, while any firmware upgrades must be procured separately as a firmware order note: firmware must be ordered as separate sub position. The controller is paired with Control Section Design 'BASIC' (B) and features a control section design type BASIC with design version 1.



No additional design features are included, and the unit arrives not equipped with interface 2 or safety interfaces, simplifying its configuration for core drive tasks. At just 1.30kg mass, this controller delivers high power density and easy handling during assembly. Its clear feature set makes it an ideal solution for servo-driven automation where precise control, reliable cooling, and networked communication are essential.

Technical Specifications

Communication Interface
MultiEthernet

Pairing Note
Paired with Control Section Design 'BASIC' (B)

Control Section Design Type
BASIC

Cooling Method
Air, internal (through integrated blower)

IP Rating
IP20

Design Version
1

Other Design Features
None

Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2

Interface 2 Type
Not equipped

Safety Interface
Not equipped

Line Series
HCS01

Mains Voltage
3 x AC 110...230 V ±10%

Device Peak Current
13 A

Power Supply Unit
Infeeding / Feeded

Product Type
HCS Drive Controller

Capacitance against housing
2×68nF

Firmware
With standard control panel

Mass
1.30kg

Why does the product code HCS01.1E-W0013_A-02-B-ET-EC-NN-NN-NN-FW specify IndraDyn Hiperface/EnDat 2.1/2.2, and how does that influence servo loop fidelity?

Those encoder interfaces deliver absolute position and robust interpolation for tightening position loop bandwidth and reducing following error. Its mixed encoder support eases motor selection while sustaining precise multi-turn feedback during power cycles.

How does MultiEthernet on HCS01.1E-W0013_A-02-B-ET-EC-NN-NN-NN-FW simplify PLC integration across diverse control platforms?

Its MultiEthernet hardware supports common industrial Ethernet stacks for enabling configuration as EtherNet/IP, PROFINET or EtherCAT without changing hardware. It lets mixed-vendor PLC environments commission faster and reuse diagnostics across networks.

How should I interpret the 13 A device peak current on HCS01.1E-W0013_A-02-B-ET-EC-NN-NN-NN-FW in dynamic axes?

Its peak current reserves cover acceleration spikes and short disturbance events to improve contouring during rapid indexing. Its correctly sizing continuous current and bus capacitance prevents nuisance trips under frequent reversals.

What thermal benefits come from “air, internal (integrated blower)” cooling on HCS01.1E-W0013_A-02-B-ET-EC-NN-NN-NN-FW?

Its internal fan drives directed airflow across heat-critical components for sustaining ratings in dense panels. It also isolates cooling from cabinet over-temperature to reduce derating compared with purely passive convection paths.

How do the internal 2×68 nF capacitors to housing in HCS01.1E-W0013_A-02-B-ET-EC-NN-NN-NN-FW aid EMC compliance?

The Y-capacitance shunts common-mode noise to protective earth for lowering conducted emissions on supply and motor cables. It helps meet EN/IEC limits and reduces encoder/UUT susceptibility in sensitive installations.

HCS011EW0013_A02BETECNNNNNNFW

HCS01 1E W0013_A 02 B ET EC NN NN NN FW

hcs01.1e-w0013-a-02-a-cc-ec-pb-l4-nn-fw

HCS1.1E-W0013_A-02-B-ET-EC-NN-NN-NN-FW

Internal Product Review

Bosch Rexroth produces the IndraDrive series HCS01.1E-W0013_A-02-B-ET-EC-NN-NN-NN-FW controller with built-in MultiEthernet networking and IndraDyn Hiperface/EnDat 2.1/2.2 feedback for accurate servo control. It operates on a rated 3×AC 110–230 V supply source, with ±10% tolerance. It come with internal-blower cooling, IP20 construction and infeeding/feeded PSU to serve in applications such as machine tools, intralogistics and robotics.

Warranty

1-year-warranty
Indramat USA 1 Year Warranty

Repair

product repair We offer a repair service for the HCS01.1E-W0013_A-02-B-ET-EC-NN-NN-NN-FW.
Indramat Is Trusted By
motion-industries-logo
3m-logo
IBM-logo
GexPro-logo
caterpillar-logo
nasa-logo
ford-logo
vallen-logo