The Bosch Rexroth Indramat HCS01.1E-W0018-A-02-A-CC-EC-EC-L3-NN-FW from the HCS IndraDrive Controllers series is a HCS Drive Controller in the HCS Compact Converter Series offering a mains voltage of 3 x AC 110…230 V ±10% and a device peak current of 18 A. This module delivers versatile performance as a power supply unit with both infeeding and feeded capabilities, ensuring seamless energy management in compact automation systems. It features an IP20 rating and an air, internal (through integrated blower) cooling method to maintain optimal operating temperatures under load. Native SERCOS III master (cross communication) support guarantees high-speed, real-time data exchange across drive networks.



The drive is built around an ADVANCED control section design type, as noted in the pairing note, and adheres to design version 1 specifications for consistent reliability. Dual encoder interfaces (IndraDyn Hiperface/EnDat 2.1/2.2) provide high-precision feedback via both Interface 1 Type and Interface 2 Type channels. Functional safety is assured with a STO (Safe Torque Off) safety interface, enabling rapid torque disable on demand. Firmware configuration requires separate ordering per the firmware order note, while no other design features were included to maintain a streamlined architecture.



Compact and robust, the HCS01.1E-W0018-A controller integrates effortlessly into standard drive cabinets and offers predictable behavior for demanding motion control tasks. Its internal blower cooling and reinforced IP20 enclosure ensure long-term stability across varied ambient conditions. Whether in packaging, assembly, or material handling applications, this controller delivers precision, safety, and scalability for industrial automation projects.

Technical Specifications

Communication Interface
SERCOS III master (cross communication)

Pairing Note
Paired with Control Section Design 'ADVANCED' (A)

Control Section Design Type
ADVANCED

Cooling Method
Air, internal (through integrated blower)

IP Rating
IP20

Design Version
1

Other Design Features
None

Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2

Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2

Safety Interface
STO (Safe Torque Off)

Line Series
HCS01

Mains Voltage
3 x AC 110...230 V ±10%

Device Peak Current
18 A

Power Supply Unit
Infeeding / Feeded

Product Type
HCS Drive Controller

What encoder options are supported, and why do dual interfaces matter for this product code?

The unit supports IndraDyn Hiperface and EnDat 2.1/2.2 to enable absolute position tracking and high-resolution velocity estimation. Its dual channels simplify commissioning (primary/aux) and allow redundancy or mixed feedback strategies for applications like gantries and synchronized conveyors.

How does the internal air (integrated blower) cooling of HCS01.1E-W0018-A-02-A-CC-EC-EC-L3-NN-FW affect cabinet design and thermal derating?

The built-in blower enhances internal convection for maintaining thermal headroom without external heat sinks. Its designers can maintain compact cabinet spacing while meeting IP20 guidelines and managing ambient-temperature-dependent derating curves.

Why is STO (Safe Torque Off) important on HCS01.1E-W0018-A-02-A-CC-EC-EC-L3-NN-FW, and how is it typically wired?

It removes the drive’s ability to generate torque without cutting mains for supporting safety categories that reduce risk during access. It’s wired via dedicated safety inputs to interlocked with external E-Stops or gate switches.

How does IP20 protection influence enclosure and environment requirements for HCS01.1E-W0018-A-02-A-CC-EC-EC-L3-NN-FW?

It implies finger-safe protection and no water ingress protection, so installation inside a suitable control cabinet is required. It is important to provide filtered airflow and comply with spacing to maintain safe operation.

What commissioning sequence helps achieve deterministic motion when multiple HCS01 drives share a SERCOS III ring?

It is recommended to establish physical ring, set IP/MAC parameters per segment and synchronize cycle/phase parameters across all nodes.

HCS011EW0018A02ACCECECL3NNFW

HCS01 1E W0018 A 02 A CC EC EC L3 NN FW

hcs01.1e-w0013-a-02-a-et-ec-da-nn-nn-fw

HCS1.1E-W0018-A-02-A-CC-EC-EC-L3-NN-FW

Internal Product Review

The Bosch Rexroth Indramat's HCS01.1E-W0018-A-02-A-CC-EC-EC-L3-NN-FW drive controller is presented in an IP20 rated enclosure and ventilation blower. It pairs an ADVANCED control section with SERCOS III master cross-communication and dual IndraDyn Hiperface/EnDat feedback for precise operations. This drive runs on a 3-phase 110–230 V source supply and supports 18 A of peak load in industrial lines such as logistics and printing.

Warranty

1-year-warranty
Indramat USA 1 Year Warranty

Repair

product repair We offer a repair service for the HCS01.1E-W0018-A-02-A-CC-EC-EC-L3-NN-FW.
Indramat Is Trusted By
motion-industries-logo
3m-logo
IBM-logo
GexPro-logo
caterpillar-logo
nasa-logo
ford-logo
vallen-logo