1-888-551-3082 | 1-919-443-0207 | sales@indramat-usa.com

HCS01.1E-W0018-A-02-A-CC-EC-EC-NN-NN-FW

HCS IndraDrive Controllers

  In-Stock, Ships 3-5 Days
Expedited Lead Times on Select Parts
1 Year Warranty Included
Free Ground Shipping
Expedited Lead Times on Select Parts
1 Year Warranty Included
Free Ground Shipping
The HCS01.1E-W0018-A-02-A-CC-EC-EC-NN-NN-FW controller from Bosch Rexroth Indramat belongs to the HCS IndraDrive Controllers series. It uses internal air cooling with an integrated blower, supports SERCOS III master communication, and delivers a peak current of 18 A at 3×AC 110–230 V ±10%. The controller has an IP20 rating and features an ADVANCED control section design. Encoder interfaces include IndraDyn Hiperface/EnDat 2.1 and 2.2.

Technical Specifications

Communication Interface
SERCOS III master (cross communication)

Pairing Note
Paired with Control Section Design 'ADVANCED' (A)

Control Section Design Type
ADVANCED

Cooling Method
Air, internal (through integrated blower)

IP Rating
IP20

Design Version
1

Other Design Features
None

Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2

Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2

Safety Interface
Not equipped

Line Series
HCS01

Mains Voltage
3 x AC 110...230 V ±10%

Device Peak Current
18 A

Power Supply Unit
Infeeding / Feeded

Product Type
HCS Drive Controller

How does SERCOS III “CC” cross-communication on HCS01.1E-W0018-A-02-A-CC-EC-EC-NN-NN-FW streamline multi-axis coordination?

It enables deterministic, Ethernet-based synchronization between drives without a central PLC for inter-axis exchange. It reduces bus latency and simplifies camming/gear functions in coordinated packaging and converting lines.

What advantages arise from the controller’s internal air cooling with integrated blower?

The integrated fan circulates cabinet air through the heat sink for maintaining thermal margins without external heat exchangers. It improves availability in compact panels if intake filtration and ambient limits match Bosch Rexroth guidelines.

Why offer dual encoder interfaces (IndraDyn Hiperface/EnDat 2.1/2.2) on this HCS01 drive?

The multi-encoder compatibility lets HCS01.1E-W0018-A-02-A-CC-EC-EC-NN-NN-FW interoperate with MSM/MSK and third-party motors for enabling absolute or incremental feedback. It eases retrofits and mixed fleets while preserving high-resolution position loops.

What does the IP20 rating imply for installation of HCS01.1E-W0018-A-02-A-CC-EC-EC-NN-NN-FW?

It requires mounting inside a protective cabinet with proper ingress protection and airflow management. It is important to maintain creepage/clearance and follow EMC wiring to meet industrial environments’ contamination and noise levels.

What is the role of the “ADVANCED” control section in HCS01.1E-W0018-A-02-A-CC-EC-EC-NN-NN-FW?

The ADVANCED section supports richer motion functions and extended interfaces compared to basic variants. It’s intended for applications needing complex profiles, cam tables and tighter loop rates on compact hardware.

HCS011EW0018A02ACCECECNNNNFW

HCS01 1E W0018 A 02 A CC EC EC NN NN FW

hcs01.1e-w0013-a-02-a-et-ec-ec-nn-nn-fw

HCS1.1E-W0018-A-02-A-CC-EC-EC-NN-NN-FW

Internal Product Review

The Bosch Rexroth Indramat’s HCS01.1E-W0018-A-02-A-CC-EC-EC-NN-NN-FW controller comes with an ADVANCED control section. It uses internal-blower air cooling and it is constructed in an IP20 rated enclosure for protection. The drive's dual encoder inputs accept IndraDyn Hiperface/EnDat 2.1/2.2. Its peak load capability is 18 A and it possess SERCOS III master to suit installation in packaging, printing and assembly/handling machines.

Warranty

1-year-warranty
Indramat USA 1 Year Warranty

Repair

product repair We offer a repair service for the HCS01.1E-W0018-A-02-A-CC-EC-EC-NN-NN-FW.
Indramat Is Trusted By
motion-industries-logo
3m-logo
IBM-logo
GexPro-logo
caterpillar-logo
nasa-logo
ford-logo
vallen-logo