HCS01.1E-W0018-A-02-A-CC-EC-EM-L3-NN-FW
HCS IndraDrive Controllers
Technical Specifications
Communication Interface
SERCOS III master (cross communication)
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder emulation
Safety Interface
STO (Safe Torque Off)
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Device Peak Current
18 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
What encoder options does the HCS01 controller support, and why does its emulation matter?
It supports IndraDyn interfaces including HIPERFACE/EnDat 2.1/2.2, plus encoder emulation for downstream devices. Its emulation lets legacy controllers “see” a compatible feedback signal for easing retrofits and mixed-vendor motor ecosystems.
How does SERCOS III master cross-communication on HCS01.1E-W0018-A-02-A-CC-EC-EM-L3-NN-FW simplify multi-axis coordination?
The SERCOS III master mode enables deterministic, real-time exchange among drives and controllers for reducing PLC burden and cycle jitter. Its cross-communication allows drive-to-drive data sharing for tightly synchronized axes in packaging, printing and handling cells.
Why is IP20 with internal-blower cooling appropriate for this product code HCS01.1E-W0018-A-02-A-CC-EC-EM-L3-NN-FW?
It is intended for cabinet mounting, while the integrated blower circulates air through the unit for thermal management. It is important to follow cabinet-level protection (e.g., IP54) and airflow guidelines to prevent conductive dust ingress.
How does STO on the HCS01 series enhance functional safety without external contactors?
It interrupts drive torque-generating energy for achieving a safe state without mechanical relays in many designs. It reduces complexity and allows faster recovery after safety events when properly validated.
How do “infeeding/feeded” power supply modes affect HCS01 system design on product code HCS01.1E-W0018-A-02-A-CC-EC-EM-L3-NN-FW?
The architecture supports front-end infeed modules or operation as a consumer on a shared DC bus. It enables energy sharing and compact layouts in multi-axis cells.
Common Misspellings
HCS011EW0018A02ACCECEML3NNFW
HCS01 1E W0018 A 02 A CC EC EM L3 NN FW
hcs01.1e-w0013-a-02-a-et-ec-em-nn-nn-fw
HCS1.1E-W0018-A-02-A-CC-EC-EM-L3-NN-FW
Internal Product Review
Bosch Rexroth designs the HCS01.1E-W0018-A-02-A-CC-EC-EM-L3-NN-FW drive controller with SERCOS III master cross-communication, STO and encoder emulation (IndraDyn Hiperface/EnDat 2.x). It accepts 3×AC 110–230 V and delivers 18 A peak current during full load. This drive pairs with ADVANCED control section, while its firmware needs to be ordered separately. It is suited to packaging, printing, handling and machine tools due its integrated air-cooled construction.