HCS01.1E-W0018-A-02-A-CC-EC-ET-L3-NN-FW
HCS IndraDrive Controllers
The HCS01.1E-W0018-A-02-A-CC-EC-ET-L3-NN-FW is an HCS Drive Controller from Bosch Rexroth Indramat's HCS IndraDrive Controllers series. It features a SERCOS III master communication interface and STO (Safe Torque Off) safety interface. Designed for ADVANCED control sections, it handles 3 x AC 110...230 V ±10% mains voltage with 18 A peak current. Internal air cooling via integrated blower ensures thermal management. With IP20 protection, dual encoder (Hiperface/EnDat) and MultiEthernet interfaces, firmware is ordered separately.
Technical Specifications
Communication Interface
SERCOS III master (cross communication)
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
MultiEthernet
Safety Interface
STO (Safe Torque Off)
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Device Peak Current
18 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
How does the STO safety interface in this HCS IndraDrive improve risk reduction during interventions?
The STO removes torque-producing energy in the power stage so the motor cannot generate rotation for meeting machine-safety practices for preventing unexpected start-up during access. It supports safe stops and maintenance workflows without fully removing mains.
Which encoder systems are supported, and why do dual encoder inputs matter for HCS01.1E-W0018-…-FW?
The controller accepts IndraDyn Hiperface and EnDat 2.1/2.2 via the multi-encoder interface. Its dual encoder capability enables primary servo feedback plus external load or linear scale feedback for higher positioning fidelity and compliance monitoring.
What industrial networks are addressed by the “ET” MultiEthernet option, and how does it aid lifecycle changes?
The ET option provides a MultiEthernet interface designed for various industrial-Ethernet ecosystems. It eases migration between controller platforms by decoupling the drive from a single fieldbus choice and preserving wiring/topologies during retrofits.
What thermal considerations follow from “air, internal” cooling via integrated blower in this IP20 device?
Its forced-air cooling demands unobstructed cabinet airflow and clearance to maintain rated current. Its housing is IP20 so place the unit in an enclosure meeting the environment’s dust ingress and pollution-degree requirements.
What commissioning software supports this product code, and how does it streamline engineering?
The IndraWorks provides planning, parameterization, commissioning and diagnostics across IndraDrive families. Its unified tooling shortens start-up, centralizes device management and simplifies firmware handling that’s ordered separately for HCS01 units.
Common Misspellings
HCS011EW0018A02ACCECETL3NNFW
HCS01 1E W0018 A 02 A CC EC ET L3 NN FW
hcs01.1e-w0013-a-02-a-et-ec-em-sb-nn-fw
HCS1.1E-W0018-A-02-A-CC-EC-ET-L3-NN-FW
Internal Product Review
The Indramat’s HCS01.1E-W0018-A-02-A-CC-EC-ET-L3-NN-FW drive controller is presented with saftey option of STO and dual-encoder (Hiperface/EnDat) feedback. It is rated for 3×AC 110–230 V ±10% and its peak load capacity is 18 A. This drive possesses SERCOS III cross-communication, MultiEthernet, IP20 rating and internally cooled design to suits different industrial systems including material handling and semiconductor tools.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0018-A-02-A-CC-EC-ET-L3-NN-FW.
Want to 