The Bosch Rexroth Indramat HCS01.1E-W0018-A-02-A-CC-EC-ET-S4-NN-FW drive controller is part of the HCS IndraDrive Controllers series from Bosch Rexroth Indramat. This compact converter unit features a Mains Voltage input of 3 x AC 110...230 V ±10% and delivers a Device Peak Current of 18 A for demanding motion control applications. Designed to be paired with the Control Section Design type ADVANCED, it provides precise and dynamic performance, making it ideal for high-speed machine tools, robots, and automated manufacturing lines.
This model employs a robust internal blower for Air, internal cooling, ensuring continuous operation under challenging thermal conditions. Communication is handled via the SERCOS III master interface with cross-communication capability, while dual interface support includes IndraDyn Hiperface/EnDat 2.1/2.2 encoder feedback and MultiEthernet for real-time data exchange. The unit’s IP20 rating safeguards the internal electronics from solid contaminants, and its design version 1 ensures compatibility with existing HCS01 line components. Firmware is managed as a separate sub-position, allowing tailored updates for specific application needs.
Built for seamless integration, the HCS01.1E converter supports both infeeding and feeded power supply configurations, simplifying installation in varied power architectures. Though no additional design features are specified, the unit’s modular construction and standardized interfaces facilitate rapid commissioning and maintenance. The compact footprint and efficient blower cooling increase system uptime and reduce energy consumption. Certified to industry IP20 standards, this controller enhances the reliability and flexibility of servo drive systems, delivering consistent torque, precise positioning, and improved throughput for industrial automation environments.
Communication Interface
SERCOS III master (cross communication)
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Firmware Order Note
Firmware must be ordered as separate sub position
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
MultiEthernet
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Device Peak Current
18 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller