HCS01.1E-W0018-A-02-A-CC-EC-NN-L3-NN-FW
HCS IndraDrive Controllers
The Bosch Rexroth Indramat HCS01.1E-W0018-A-02-A-CC-EC-NN-L3-NN-FW from the HCS IndraDrive Controllers series is a compact yet powerful HCS Drive Controller designed for versatile industrial applications. This controller operates on a three-phase Mains Voltage 3 x AC 110...230 V ±10% supply and delivers a Device Peak Current of 18 A to downstream converters. Communication is handled via the Communication Interface SERCOS III master (cross communication), ensuring real-time data exchange and synchronization across multiple axes. The unit’s Cooling Method: Air, internal (through integrated blower) and IP Rating: IP20 enclosure balance efficient heat dissipation with environmental protection for control cabinets.
Engineered for flexible integration, this controller features a Control Section Design Type ADVANCED architecture and is Paired with Control Section Design 'ADVANCED' (A) for seamless compatibility. Encoder feedback is supported through Interface 1 Type Encoder IndraDyn Hiperface/EnDat 2.1/2.2, while Interface 2 Type Not equipped simplifies configuration when additional inputs are unnecessary. A Safety Interface STO (Safe Torque Off) port fortifies machine safety by instantly removing torque generation. The Power Supply Unit Infeeding / Feeded topology accommodates both supply and regeneration modes, and the Design Version 1 designation identifies the current hardware release. Note that Firmware must be ordered as separate sub position, providing flexibility in software revision management.
Designed to streamline complex drive networks, the HCS01.1E controller leverages cross-communication capabilities and a robust safety interface to maximize uptime and protect personnel. Its internal blower and IP20-rated housing allow installation in tightly packed control cabinets without sacrificing cooling performance. With advanced feedback support and a standardized power supply design, this controller is an ideal solution for packaging machines, gantry systems, and high-performance servo applications.
Technical Specifications
Communication Interface
SERCOS III master (cross communication)
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
Safety Interface
STO (Safe Torque Off)
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Device Peak Current
18 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
What differentiates the ADVANCED control section in HCS01.1E-W0018-A-02-A-CC-EC-NN-L3-NN-FW from BASIC/ECONOMY variants?
The ADVANCED option enables SERCOS III master cross-communication (CC) for deterministic, coordinated multi-axis data exchange and synchronization. It also supports multi-encoder evaluation and integrated safety options, streamlining complex motion architectures.
Which feedback interfaces are native, and why are they relevant to servo tuning? (code: …-W0018-…-CC-EC-…-FW)
The multi-encoder interface supports IndraDyn HIPERFACE® and EnDat 2.1/2.2 among others for enabling high-resolution position data and efficient commutation. Its accurate feedback improves loop bandwidth and reduces following error in demanding motion profiles.
How does the internal-air cooling and IP20 enclosure affect cabinet design?
The blower cooling with IP20 rating targets control-cabinet installations for simplifying ducting while maintaining thermal headroom. Its correct spacing and airflow paths preserve component life and prevent thermal derating for HCS01.1E-W0018-A-02-A-CC-EC-NN-L3-NN-FW.
What is the function of the L3 STO safety interface on this unit?
It removes drive-generated torque via a hardware safety channel for achieving a defined safe state without mechanical disengagement. It reduces wiring complexity compared to external contactors for many risk-reduction scenarios.
How does the infeeding/feeded power topology assist energy management? (code: HCS01.1E-W0018-A-02-A-CC-EC-NN-L3-NN-FW)
Its configurations allow sharing DC-bus energy and handling regeneration efficiently for minimizing external braking resistors. It supports compact multi-axis clusters with improved energy utilization and simplified wiring.
Common Misspellings
HCS011EW0018A02ACCECNNL3NNFW
HCS01 1E W0018 A 02 A CC EC NN L3 NN FW
hcs01.1e-w0013-a-02-a-et-ec-nn-s4-nn-fw
HCS1.1E-W0018-A-02-A-CC-EC-NN-L3-NN-FW
Internal Product Review
Bosch Rexroth Indramat produces the HCS01.1E-W0018-A-02-A-CC-EC-NN-L3-NN-FW drive controller for rated voltage source of 3×AC 110–230 V input and 18 A device peak to feed controllers. It possesses IP20 protection from external pollutants and uses internal-air cooling mechanism. This drive's Hiperface/EnDat feedback and STO suit packaging, printing, handling and semiconductor equipment. Its infeeding/feeded topology streamlines energy sharing and makes the layout cabinet-friendly to simplify multi-axis networks.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0018-A-02-A-CC-EC-NN-L3-NN-FW.
Want to 