The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-A-CC-EC-EC-S4-NN-FW is an advanced HCS Drive Controller from the HCS IndraDrive Controllers series. It features a SERCOS III master interface, supports 3x AC 200...500 V ±10% mains voltage and delivers 18 A peak. Cooling is via an integrated blower and offers IP20 protection. Dual encoder interfaces (Hiperface/EnDat 2.1/2.2) and an ADVANCED control section (design version 1) ensure high performance; firmware must be ordered separately.
Technical Specifications
Communication Interface
SERCOS III master (cross communication)
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Device Peak Current
18 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
What feedback configuration challenges may occur with the HCS01.1E-W0018-A-03-A-CC-EC-EC-S4-NN-FW in dual-encoder setups?
It supports Hiperface and EnDat 2.1/2.2 protocols through dual encoder ports. Synchronizing multi-source feedback demands precise signal routing and electrical isolation.
How does the ADVANCED control section architecture improve servo stability under dynamic load shifts?
It executes high-frequency internal control loops with minimal delay. This reduces overshoot and improves responsiveness in demanding motion sequences.
How does the HCS01.1E-W0018-A-03-A-CC-EC-EC-S4-NN-FW maintain signal precision in synchronized drive networks?
The SERCOS III master interface provides low-latency, deterministic communication. It ensures consistent command timing in high-speed multi-axis control.
What thermal management strategy supports peak current delivery without external fans?
An integrated blower circulates cooling air internally across heat-generating zones. This maintains stable thermal conditions even at 18 A peak output.
How does the IP20 protection class limit installation flexibility in industrial layouts?
It restricts deployment to sealed, dust-free environments with controlled airflow. Additional enclosures are required for exposed or high-particulate zones.
Common Misspellings
HCS011EW0018A03ACCECECS4NNFW
HCS01 1E W0018 A 03 A CC EC EC S4 NN FW
hcs01.1e-w0018-a-02-a-cc-ec-ec-nn-nn-fw
HCS1.1E-W0018-A-03-A-CC-EC-EC-S4-NN-FW
Internal Product Review
The Rexroth Indramat HCS01.1E-W0018-A-03-A-CC-EC-EC-S4-NN-FW is a high-efficiency drive controller capable of handling 3x AC 200–500 V ±10% input. It boasts SERCOS III communication, 18 A peak output, IP20 protection, and integrated blower cooling. The dual Hiperface and EnDat encoder interfaces enable precise feedback and motion control.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0018-A-03-A-CC-EC-EC-S4-NN-FW.
Want to 