The HCS01.1E-W0018-A-03-A-CC-EC-NN-L3-NN-FW drive controller from Bosch Rexroth Indramat is part of the HCS IndraDrive Controllers series. It uses internal air cooling via an integrated blower, has an IP20 protection rating, and delivers a peak current of 18 A. The unit features a Safe Torque Off safety interface and supports an IndraDyn Hiperface/EnDat 2.1/2.2 encoder. Firmware must be ordered as a separate subposition.

Technical Specifications

Communication Interface
SERCOS III master (cross communication)

Pairing Note
Paired with Control Section Design 'ADVANCED' (A)

Control Section Design Type
ADVANCED

Cooling Method
Air, internal (through integrated blower)

IP Rating
IP20

Design Version
1

Other Design Features
None

Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2

Interface 2 Type
Not equipped

Safety Interface
STO (Safe Torque Off)

Line Series
HCS01

Mains Voltage
3 x AC 200...500 V ±10%

Device Peak Current
18 A

Power Supply Unit
Infeeding / Feeded

Product Type
HCS Drive Controller

Series
HCS Compact Converter Series

How does the HCS01.1E-W0018-A-03-A-CC-EC-NN-L3-NN-FW handle safety shutdowns in high-risk motion tasks?

It includes an integrated Safe Torque Off (STO) interface for SIL-compliant safety stops. This allows safe motor deactivation without disrupting power supply lines.

How does the encoder interface support closed-loop stability in high-resolution axis control?

It supports IndraDyn Hiperface and EnDat 2.1/2.2 protocols for precise feedback. This maintains real-time position accuracy across dynamic load changes.

What cooling method is used in the HCS01.1E-W0018-A-03-A-CC-EC-NN-L3-NN-FW to sustain high peak currents?

An integrated blower circulates air internally to manage thermal buildup. This supports stable delivery of 18 A peak current under continuous cycling.

How does firmware separation contribute to lifecycle flexibility during controller deployment?

The model's firmware must be ordered as a separate subposition based on application needs. This approach allows version-specific features without altering hardware baselines.

What protection considerations are required for deployment in standard industrial cabinets?

The unit carries an IP20 rating, suitable for dry, filtered enclosures. External shielding is required in environments with dust, moisture, or airborne oils.

HCS011EW0018A03ACCECNNL3NNFW

HCS01 1E W0018 A 03 A CC EC NN L3 NN FW

hcs01.1e-w0018-a-02-a-cc-ec-nn-s4-nn-fw

HCS1.1E-W0018-A-03-A-CC-EC-NN-L3-NN-FW

Internal Product Review

The HCS01.1E-W0018-A-03-A-CC-EC-NN-L3-NN-FW drive controller from Bosch Rexroth offers Safe Torque Off (STO) functionality for enhanced operational safety. It supports IndraDyn Hiperface/EnDat encoders, delivers 18 A peak current, and carries an IP20 rating. The internal blower-based air cooling ensures consistent thermal management.

Warranty

1-year-warranty
Indramat USA 1 Year Warranty

Repair

product repair We offer a repair service for the HCS01.1E-W0018-A-03-A-CC-EC-NN-L3-NN-FW.
Indramat Is Trusted By
motion-industries-logo
3m-logo
IBM-logo
GexPro-logo
caterpillar-logo
nasa-logo
ford-logo
vallen-logo