HCS01.1E-W0018-A-03-A-CC-EC-PB-L4-NN-FW
HCS IndraDrive Controllers
Technical Specifications
Communication Interface
SERCOS III master (cross communication)
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
PROFIBUS
Safety Interface
STO (Safe Torque Off) and SBC (Safe Brake Control)
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Device Peak Current
18 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
How does HCS01.1E-W0018-A-03-A-CC-EC-PB-L4-NN-FW enable precise axis coordination under high-speed demands?
The integrated SERCOS III master interface provides deterministic communication with minimal latency. This ensures real-time synchronization in multi-axis motion systems with high timing sensitivity.
What role does the blower-based design play in controlling heat during continuous duty?
An internal blower enables forced-air cooling directly across internal components. This keeps thermal rise in check under prolonged high-current loads and dense cabinet conditions.
How can safety be maintained without shutting down drive diagnostics?
This unit includes STO and SBC interfaces for safe torque and brake control. They allow safety-rated stops while retaining communication with higher-level controllers.
How should IP20-rated units like this one be installed in industrial environments?
With only IP20 protection, it prevents solid object ingress but not dust or moisture. Installation inside sealed, ventilated enclosures is essential for reliable long-term operation.
Can HCS01.1E-W0018-A-03-A-CC-EC-PB-L4-NN-FW run immediately with all functions upon delivery?
No, the firmware must be ordered separately and matched to the ADVANCED control section. This ensures compatibility with required drive functions and safety configurations.
Common Misspellings
HCS011EW0018A03ACCECPBL4NNFW
HCS01 1E W0018 A 03 A CC EC PB L4 NN FW
hcs01.1e-w0018-a-02-a-et-ec-nn-l3-nn-fw
HCS1.1E-W0018-A-03-A-CC-EC-PB-L4-NN-FW
Internal Product Review
The HCS01.1E-W0018-A-03-A-CC-EC-PB-L4-NN-FW drive controller by Bosch Rexroth delivers a peak current of 18 A. It includes IP20-rated protection, internal blower cooling, and dual safety functions (STO/SBC), operating across 3 x AC 200–500 V ±10%. The communications are handled via SERCOS III and PROFIBUS interfaces.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0018-A-03-A-CC-EC-PB-L4-NN-FW.
Want to 