The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-B-ET-EC-DA-S4-NN-FW from the HCS IndraDrive Controllers series is a high-performance HCS Drive Controller in the HCS01 line series, delivering a device peak current of 18 A and operating on a three-phase 3 x AC 200...500 V ±10% mains voltage. Communication is streamlined via a MultiEthernet interface, while precision feedback is ensured through the Encoder IndraDyn Hiperface/EnDat 2.1/2.2 connection. The controller’s robust IP20 rating protects internal components, and the compact unit integrates seamlessly into modern drive cabinets. Design version 1 establishes a solid foundation for predictable performance and long-term support.
With an internal blower providing air, internal (through integrated blower) cooling, the controller maintains optimal thermal conditions even under continuous heavy loads. The Power Supply Unit supports both infeeding and feeded operation, ensuring bidirectional energy flow and efficient regeneration. A BASIC control section design type, paired with Control Section Design 'BASIC' (B), simplifies commissioning and standardises wiring across multiple installations. Firmware must be ordered as a separate sub position, allowing for tailored updates and future function extensions. Other design features are minimal, focusing on core functionality and industrial reliability.
Engineered for compactness and ease of integration, this HCS controller minimises cabinet space without sacrificing power density or interface flexibility. Its combination of high peak current capacity, advanced encoder compatibility, and standardised communication protocols makes it ideal for precision motion control in packaging, robotics, and machine tool applications. With a focus on modular upgrades and dependable operation, the HCS01.1E-W0018-A-03-B-ET-EC-DA-S4-NN-FW ensures streamlined installation and efficient lifecycle management.
Communication Interface
MultiEthernet
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Firmware Order Note
Firmware must be ordered as separate sub position
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Device Peak Current
18 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller