HCS01.1E-W0018-A-03-B-ET-EC-NN-L3-NN-AW
HCS IndraDrive Controllers
Technical Specifications
Communication Interface
MultiEthernet
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
Safety Interface
STO (Safe Torque Off)
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Device Peak Current
18 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
How does HCS01.1E-W0018-A-03-B-ET-EC-NN-L3-NN-AW handle temperature?
It operates reliably up to 40°C under nominal conditions to ensure full-rated performance. Higher ambient temperatures may require derating or external cooling integration.
What pollution degree classification is applied here?
It is rated for Pollution Degree 2, meaning only non-conductive pollution is acceptable. This ensures safe operation in controlled, industrial cabinet environments.
How do altitude conditions affect the controller?
Installation above 1000 meters may impact cooling and dielectric strength. Derating guidelines must be followed to maintain safe thermal and electrical operation.
Why is cabinet airflow design critical here?
Clearances of 90 mm top/bottom and 0 mm sides ensure adequate air movement for heat dissipation. Insufficient airflow can lead to premature thermal shutdown.
What enclosure requirements protect the unit externally?
The device must be installed in a sealed cabinet to prevent ingress of moisture and contaminants. This maintains its integrity in demanding industrial conditions.
Common Misspellings
HCS011EW0018A03BETECNNL3NNAW
HCS01 1E W0018 A 03 B ET EC NN L3 NN AW
hcs01.1e-w0018-a-03-a-cc-ec-em-nn-nn-fw
HCS1.1E-W0018-A-03-B-ET-EC-NN-L3-NN-AW
Internal Product Review
The HCS01.1E-W0018-A-03-B-ET-EC-NN-L3-NN-AW by Bosch Rexroth is a drive controller from the HCS01 series, operating at 3 x AC 200–500 V with 18 A peak current. It supports MultiEthernet and EnDat/IndraDyn Hiperface interfaces. It is often used in robotics, conveyor systems, and machine automation tasks.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0018-A-03-B-ET-EC-NN-L3-NN-AW.
Want to 