HCS01.1E-W0018-A-03-E-S3-EC-NN-L4-NN-FW is a drive controller by Bosch Rexroth Indramat. Part of the HCS IndraDrive Controllers series, it supports SERCOS III communication and internal air cooling. It delivers a peak current of 18 A and accepts three-phase AC 200–500 V ±10%. Safety functions include Safe Torque Off and Safe Brake Control, and it is rated IP20.

Technical Specifications

Communication Interface
SERCOS III

Pairing Note
Paired with Control Section Design 'ECONOMY' (E)

Control Section Design Type
ECONOMY

Cooling Method
Air, internal (through integrated blower)

IP Rating
IP20

Design Version
1

Other Design Features
None

Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2

Interface 2 Type
Not equipped

Safety Interface
STO (Safe Torque Off) and SBC (Safe Brake Control)

Line Series
HCS01

Mains Voltage
3 x AC 200...500 V ±10%

Device Peak Current
18 A

Power Supply Unit
Infeeding / Feeded

Product Type
HCS Drive Controller

What ambient temperature must be maintained for safe operation?

The ambient temperature must not exceed 40 °C under nominal load to avoid thermal stress and internal derating. The controller may require forced cooling or derating above this threshold.

What moisture and condensation constraints apply to installation?

The drive must be installed in areas where condensation cannot occur to protect against insulation breakdown. The enclosure should maintain internal humidity below dew point thresholds.

How does HCS01.1E-W0018-A-03-E-S3-EC-NN-L4-NN-FW handle airborne contamination?

The unit is rated for Pollution Degree 2, restricting use to environments with non-conductive dust only. The cabinet must filter or seal against conductive contaminants and particles.

What grounding requirements suit higher leakage current levels?

The equipment grounding conductor must meet minimum cross-section specifications (≥ 10 mm² copper or equivalent). The grounding ensures safe discharge of leakage currents exceeding 3.5 mA under fault or normal conditions.

How must spacing clearances be managed in chassis mounting?

The controller requires at least 90 mm clearance above and below for proper convection airflow. The spacing avoids heat buildup and ensures thermal stability in dense cabinet layouts.

HCS011EW0018A03ES3ECNNL4NNFW

HCS01 1E W0018 A 03 E S3 EC NN L4 NN FW

hcs01.1e-w0018-a-03-a-et-ec-nn-l3-nn-fw

HCS1.1E-W0018-A-03-E-S3-EC-NN-L4-NN-FW

Internal Product Review

The HCS01.1E-W0018-A-03-E-S3-EC-NN-L4-NN-FW by Bosch Rexroth supports EtherCAT connectivity, includes a multi-encoder interface with EnDat and Hiperface compatibility, and features safety level L4 with Safe Torque Off and Safe Brake Control. Its IP20-rated design with internal air cooling suits automated assembly, packaging, and robotics environments.

Warranty

1-year-warranty
Indramat USA 1 Year Warranty

Repair

product repair We offer a repair service for the HCS01.1E-W0018-A-03-E-S3-EC-NN-L4-NN-FW.
Indramat Is Trusted By
motion-industries-logo
3m-logo
IBM-logo
GexPro-logo
caterpillar-logo
nasa-logo
ford-logo
vallen-logo