The Bosch Rexroth Indramat HCS01.1E-W0028-A-03-A-CC-EC-EM-NN-NN-FW from the HCS IndraDrive Controllers series is a high-performance HCS Drive Controller designed for demanding automation tasks. Part of the specialized HCS01 line series, this compact converter supports a mains voltage of 3 x AC 200...500 V ±10% and delivers a device peak current of 28 A for precision motor control. Integration into advanced system topologies is enabled by the native Communication Interface: SERCOS III master (cross communication) and the mandatory Pairing Note: Paired with Control Section Design 'ADVANCED' (A). The controller’s robust architecture and detailed technical documentation make it ideal for complex machine tools, packaging systems, and robotics applications.
Featuring an internal air cooling method through an integrated blower, the HCS01.1E-W0028-A ensures consistent thermal performance in densely packed control cabinets. The built-in Control Section Design Type: ADVANCED offers enhanced processing capacity and diagnostic capabilities, while the Interface 1 Type: Encoder IndraDyn Hiperface/EnDat 2.1/2.2 and Interface 2 Type: Encoder emulation enable flexible feedback configurations without additional adapters. Though Safety Interface: Not equipped by default, the unit’s modular design allows for external safety expansions to meet specific machine directives. With a Power Supply Unit: Infeeding/Feeded topology and an IP20 enclosure rating, this controller balances accessibility with protection against solid contaminants.
Version management is simplified by the Design Version: 1 identifier, ensuring that firmware revisions and hardware updates align seamlessly. Note that the Firmware Order Note: Firmware must be ordered as separate sub position to guarantee compatibility with custom application profiles. In addition, there are Other Design Features: None, highlighting the module’s streamlined construction for ease of maintenance and rapid field replacement.
Communication Interface
SERCOS III master (cross communication)
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Firmware Order Note
Firmware must be ordered as separate sub position
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder emulation
Safety Interface
Not equipped
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Device Peak Current
28 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller