HCS01.1E-W0054-A-03-A-CC-EC-EC-L4-NN-FW
HCS IndraDrive Controllers
The HCS01.1E-W0054-A-03-A-CC-EC-EC-L4-NN-FW is a HCS Drive Controller from Bosch Rexroth Indramat's HCS IndraDrive Controllers series. It features a SERCOS III master (cross communication) interface and is paired with control section design ADVANCED. Cooled by internal air via an integrated blower, it delivers a device peak current of 54 A on 3 x AC 200...500 V ±10%. Equipped with IndraDyn Hiperface/EnDat 2.1/2.2 encoder interfaces and STO (Safe Torque Off) and SBC (Safe Brake Control) safety functions, it meets IP20 protection and requires firmware ordered separately.
Technical Specifications
Communication Interface
SERCOS III master (cross communication)
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Safety Interface
STO (Safe Torque Off) and SBC (Safe Brake Control)
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Device Peak Current
54 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
Which safety interfaces are supported by HCS01.1E-W0054-A-03-A-CC-EC-EC-L4-NN-FW?
HCS01.1E-W0054-A-03-A-CC-EC-EC-L4-NN-FW includes STO and SBC.
What encoder interface types does HCS01.1E-W0054-A-03-A-CC-EC-EC-L4-NN-FW use?
HCS01.1E-W0054-A-03-A-CC-EC-EC-L4-NN-FW supports IndraDyn Hiperface and EnDat 2.1/2.2.
What is the firmware requirement for HCS01.1E-W0054-A-03-A-CC-EC-EC-L4-NN-FW?
Firmware must be ordered as a separate sub position for HCS01.1E-W0054-A-03-A-CC-EC-EC-L4-NN-FW.
What is the design version of HCS01.1E-W0054-A-03-A-CC-EC-EC-L4-NN-FW?
HCS01.1E-W0054-A-03-A-CC-EC-EC-L4-NN-FW has design version 1.
Does HCS01.1E-W0054-A-03-A-CC-EC-EC-L4-NN-FW feature internal cooling?
HCS01.1E-W0054-A-03-A-CC-EC-EC-L4-NN-FW uses internal air cooling via a blower.
Common Misspellings
HCS011EW0054A03ACCECECL4NNFW
HCS01 1E W0054 A 03 A CC EC EC L4 NN FW
hcs01.1e-w0028-a-03-b-et-ec-ec-l2-nn-fw
HCS1.1E-W0054-A-03-A-CC-EC-EC-L4-NN-FW
Internal Product Review
The HCS01.1E-W0054-A-03-A-CC-EC-EC-L4-NN-FW performs consistently in continuous use. It maintains smooth operation and reliable control. Users appreciate its predictable behavior in different conditions. It integrates without difficulty and supports dependable performance across setups. This model is favored for stable and steady operational results.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0054-A-03-A-CC-EC-EC-L4-NN-FW.
Want to 