1-888-551-3082 | 1-919-443-0207 sales@indramat-usa.com

R911325245 (HCS01.1E-W0013-A-02-B-ET-EC-NN-NN-NN-FW)

HCS IndraDrive Controllers

  In-Stock, Ships 3-5 Days
Expedited Lead Times on Select Parts
1 Year Warranty Included
Free Ground Shipping
Expedited Lead Times on Select Parts
1 Year Warranty Included
Free Ground Shipping
The Bosch Rexroth MPN R911325245 (HCS01.1E-W0013-A-02-B-ET-EC-NN-NN-NN-FW) is a HCS01 series drive controller designed for G1 mounting in control cabinets, operating with a mains input of 3 x AC 110–230 V ±10% and a device peak current of 13 A. This IP20 rated unit uses internal air cooling via an integrated blower and supports communication through MultiEthernet. The control section is of the BASIC design type (B) and pairs with external synchronous or asynchronous motors. It provides an encoder interface compatible with IndraDyn Hiperface/EnDat 2.1/2.2 and requires protection against conductive dust, electromagnetic interference compliant installation (including signal line shielding), and proper grounding. The controller must be installed to prevent foreign material ingress, is not equipped with additional safety or second interfaces, and hardware modifications are not permitted. Derating occurs above 40°C ambient temperature. Firmware must be ordered separately. All service and maintenance must be performed while the unit is de-energized.

Technical Specifications

Mounting Position
G1

Usage Location
Control cabinet

Operating Temperature
0°C-40°C

Short Circuit Current Rating
42000Amps

Requirements
EMC regulations compliant, Fuse installation

Signal Line Shielding
Required

Hardware Modification
Not allowed

Possible Risk
Electric shock if components misused

Voltage Rating
Over 50V for electrical parts

Usage Environment
Not for industrial environments

Firmware
To be procured separately

Certification
UL Listed and CSA Certified

Functionality
Operates as frequency converter

Mounting Compatibility
Standard, left-hand or right-hand

Motor Compatibility
Synchronous and asynchronous motors

Performance
Derated when ambient conditions are exceeded

Installation
De-energized before working on live parts

Backup Support
One-year.

What motion-feedback options are available, and why do Hiperface/EnDat 2.1/2.2 matter for this code?

The product code HCS01.1E-W0013-A-02-B-ET-EC-NN-NN-NN-FW includes an IndraDyn encoder interface supporting Hiperface/EnDat 2.1/2.2 for ensuring absolute feedback and fine interpolation. It elevates positional fidelity and smooth velocity loops in servo applications.

How does the MultiEthernet interface in HCS01.1E-W0013-A-02-B-ET-EC-NN-NN-NN-FW simplify control integration across different PLC ecosystems?

Its software-configurable MultiEthernet supports SERCOS III, PROFINET IO, EtherNet/IP and EtherCAT for enabling one hardware variant to fit diverse fieldbus stacks and third-party motors with minimal re-engineering. It reduces cabinet variants and accelerates commissioning.

How does the internal air-cooling blower affect continuous operation of HCS01.1E-W0013-A-02-B-ET-EC-NN-NN-NN-FW?

The integrated blower maintains thermal steadiness under sustained load for stabilizing current delivery and avoiding thermal derating. It helps sustain loop bandwidth during repetitive duty cycles without resorting to external fan trays.

What supply specifications (voltage and current) define its dynamic envelope, and what applications benefit?

It is rated 3×AC 110–230 V ±10% with 13 A device peak current, it accommodates brown-outs and short acceleration bursts. Its profile suits pick-and-place, form-fill-seal axes, die-cutters, light machine tools and converting lines.

Why does the BASIC control section (B) and separately ordered firmware matter for lifecycle flexibility on HCS01.1E-W0013-A-02-B-ET-EC-NN-NN-NN-FW?

The BASIC section gives a lean baseline while firmware (ordered separately) tailors functions, safety sets and motion profiles. It lets OEMs scale features via IndraDrive firmware options without hardware swaps.

HCS01.1EW0013A02BETECNNNNNNFW

HCS011E-W0013-A-02-B-ET-EC-NN-NN-NN-FW

HCS011EW0013A02BETECNNNNNNFW

HCSO1.1E-WOO13-A-O2-B-ET-EC-NN-NN-NN-FW

HCS01 1E W0013 A 02 B ET EC NN NN NN FW

hcs01.1e-w0013-a-02-a-cc-ec-ec-l3-nn-fw

HCS1.1E-W0013-A-02-B-ET-EC-NN-NN-NN-FW

Internal Product Review

The HCS01.1E-W0013-A-02-B-ET-EC-NN-NN-NN-FW compact controller from Bosch combines a BASIC control section, MultiEthernet and IndraDyn Hiperface/EnDat feedback for precise servo regulation. It needs a 3×AC 110–230 V ±10% supply source to operate. Its current output is specified as 13 A peak to fits into printing, semiconductor tools and medical automation cells.

Warranty

1-year-warranty
Indramat USA 1 Year Warranty

Repair

product repair We offer a repair service for the HCS01.1E-W0013-A-02-B-ET-EC-NN-NN-NN-FW.
Indramat Is Trusted By
motion-industries-logo
3m-logo
IBM-logo
GexPro-logo
caterpillar-logo
nasa-logo
ford-logo
vallen-logo