R911328426 (HCS01.1E-W0013-A-02-E-S3-EC-NN-NN-NN-FW)
HCS IndraDrive Controllers
Technical Specifications
Product Group
HCS
Communication Module
SERCOS III / EtherCAT
Control Panel
HAP01
Width
50mm
Height
215mm
Usage Environment
Industrial environments
Control Category
C3 (IEC 61800-3)
Maintenance
Qualified personnel
Electrical Connection Points
Live during operation
Brake Control
Holds the brake of associated motor
Materials
Environmentally safe
Suitable Motors
Third-party motors that satisfy the voltage loads
Delivery
Global shipping
Frequently Asked Questions
How do the encoder interfaces (IndraDyn Hiperface/EnDat 2.1/2.2) on HCS01.1E-W0013-A-02-E-S3-EC-NN-NN-NN-FW aid feedback selection?
The multi-encoder front-end accepts common absolute and incremental protocols for enabling pairings with IndraDyn motors or third-party feedbacks. Its flexibility simplifies retrofit and preserves high-resolution position/velocity loops.
Why is the ECONOMY control section (“E”) appropriate for this code, and what does it imply for commissioning?
The ECONOMY variant integrates power and control in a compact controller with basic HMI that is suitable for lower-kW applications. It streamlines setup while retaining key motion functions and parameterization via IndraWorks.
What advantages does SERCOS III bring on the HCS01.1E-W0013-A-02-E-S3-EC-NN-NN-NN-FW in synchronous multi-axis cells?
The SERCOS III provides deterministic, cycle-accurate motion and diagnostics over Ethernet for simplifying coordinated axis control and topology scaling. It reduces PLC load and eases integration with Bosch Rexroth IndraDrive ecosystems.
What environments match the IP20 enclosure, and what safeguards are recommended?
The IP20 suits cabinet-mounted industrial environments with limited ingress risk, while it’s not intended for washdown or direct exposure. It is recommended to use enclosed panels with proper filtering and spacing to maintain protection.
What mains tolerance and topology does the HCS01.1E-W0013-A-02-E-S3-EC-NN-NN-NN-FW accept, and why is ±10% significant?
It operates from 3×AC 110…230 V with ±10% tolerance for covering global low-voltage cabinets. It accommodates brownouts or supply variation without nuisance trips to aid uptime in mixed-utility plants.
Common Misspellings
HCS011EW0013A02ES3ECNNNNNNFW
HCS01 1E W0013 A 02 E S3 EC NN NN NN FW
hcs01.1e-w0013-a-02-a-cc-ec-pb-l3-nn-fw
HCS1.1E-W0013-A-02-E-S3-EC-NN-NN-NN-FW
Internal Product Review
The Indramat’s HCS01.1E-W0013-A-02-E-S3-EC-NN-NN-NN-FW drive controller combines SERCOS III, IP20 housing and internal-blower cooling with a 3×AC 110–230 V (±10%) supply. Its version 1, ECONOMY control section, multi-encoder (Hiperface/EnDat 2.1/2.2) and 13 A peak suit packaging, machine tools and printing lines. The unit's firmware can be ordered separately according to the need of specifications.