The R911331051 (HCS01.1E-W0018-A-03-B-ET-EC-PB-NN-AA-FW) is a Rexroth Indramat single-axis drive controller from the HCS01 line series, designed for applications that require compatibility with multi-Ethernet and PROFIBUS interfaces. It supports devices requiring multi-encoder inputs via IndraDyn Hiperface/EnDat 2.1/2.2, operates with a three-phase AC power supply of 200–500 V (±10% tolerance), and provides a maximum peak current of 18 A with a continuous current of 7 A. This unit features the BASIC control section (Design Type B), internal air cooling through an integrated blower, an IP20 protection rating, a standard operating panel with four navigation keys and a single-line display, and is supplied without a safety interface. Firmware must be ordered as a separate sub-position.

Technical Specifications

Product Type
Drive Converter

Design
Single-Axis Basic Drive Controller

Operation
Requires Configuration

Peak Load Current
18A

Continuous Operation Current
7A

Power Supply Unit Requirement
Three-Phase AC Power Supply With 200 500 V Output

Mains Voltage Frequency
Allows 10% Tolerance

Interface Support
Multi-Ethernet Communication & PROFIBUS

Supplier
Indramat USA

What is the maximum ambient temperature supported?

The maximum allowable ambient temperature is 40°C for rated performance and thermal stability. The controller must be derated or ventilated in hotter environments.

How do spacing clearances affect cabinet integration?

The unit requires 90 mm of clearance above and below to ensure proper convection cooling. The specified spacing prevents overheating and supports safe operation.

What protection class applies to general installations?

The device is typically installed within an IP54 or higher-rated enclosure for dust and moisture resistance. The external cabinet must match local environmental protection needs.

How does this controller handle pollution degree?

The controller is rated for Pollution Degree 2, meaning it must operate in dry, clean environments with minimal conductive contamination. The rating supports reliable operation in closed industrial cabinets.

What grounding rules apply in high-leakage systems?

The device has leakage current >3.5 mA, requiring robust protective grounding with specific conductor sizing. The grounding must ensure both personnel safety and EMC compliance.

HCS011EW0018A03BETECPBNNAAFW

HCS01 1E W0018 A 03 B ET EC PB NN AA FW

hcs01.1e-w0018-a-03-a-cc-ec-pb-s4-nn-fw

HCS1.1E-W0018-A-03-B-ET-EC-PB-NN-AA-FW

Internal Product Review

The Rexroth HCS01.1E-W0018-A-03-B-ET-EC-PB-NN-AA-FW drive controller supports MultiEthernet communication and offers STO safety. It includes a BASIC control section and internal blower cooling for reliable operation under continuous load. The unit suits automated packaging, synchronised gantry systems, and multi-axis motion control in smart manufacturing.