The R911331681 (HCS01.1E-W0018-A-03-E-S3-EC-NN-L4-NN-FW) is a drive controller designed for industrial applications, operating with a three-phase AC input voltage of 200 to 500 V at up to 18 A device peak current. The device supports communication via SERCOS III and incorporates an ECONOMY control section design, internal air cooling, and an IP20 rating. It is suited for installation within a control cabinet and is compatible with IndraDyn, Hiperface, and EnDat 2.1/2.2 encoders. Safety features include Safe Torque Off (STO) and Safe Brake Control (SBC). Operation is specified from 0 to 40°C and 0 to 1000 m altitude, with performance de-rating up to 55°C or 4000 m. Firmware must be ordered separately.

Technical Specifications

Application
Commercial and Industrial

Maximum Current
18 Amps

Input Voltage
200 to 500 Volts AC

Phases
Three-phase

Temperature Range
0 to 40 degrees Celsius

Elevation
0 to 1000 meters

Output De-rating Temperature
40 to 55 degrees Celsius

Maximum Operating Temperature
55 degrees Celsius

Maximum Elevation
4000 meters

Relative Humidity
5 to 95%

Absolute Humidity
1 to 29 g/m3

Climatic Degree
3K3

Pollution Degree
2

IP Rating
IP20

Communication
SERCOS/EtherCat

Encoder Interface
Multi-encoder

Safety Features
Safe torque off, Safe brake control

Control Panel
Standard

Installation
Qualified personnel only

What ambient temperature must be maintained for safe operation?

The ambient temperature must not exceed 40 °C under nominal load to avoid thermal stress and internal derating. The controller may require forced cooling or derating above this threshold.

What moisture and condensation constraints apply to installation?

The drive must be installed in areas where condensation cannot occur to protect against insulation breakdown. The enclosure should maintain internal humidity below dew point thresholds.

How does HCS01.1E-W0018-A-03-E-S3-EC-NN-L4-NN-FW handle airborne contamination?

The unit is rated for Pollution Degree 2, restricting use to environments with non-conductive dust only. The cabinet must filter or seal against conductive contaminants and particles.

What grounding requirements suit higher leakage current levels?

The equipment grounding conductor must meet minimum cross-section specifications (≥ 10 mm² copper or equivalent). The grounding ensures safe discharge of leakage currents exceeding 3.5 mA under fault or normal conditions.

How must spacing clearances be managed in chassis mounting?

The controller requires at least 90 mm clearance above and below for proper convection airflow. The spacing avoids heat buildup and ensures thermal stability in dense cabinet layouts.

HCS011EW0018A03ES3ECNNL4NNFW

HCS01 1E W0018 A 03 E S3 EC NN L4 NN FW

hcs01.1e-w0018-a-03-a-et-ec-nn-l3-nn-fw

HCS1.1E-W0018-A-03-E-S3-EC-NN-L4-NN-FW

Internal Product Review

The HCS01.1E-W0018-A-03-E-S3-EC-NN-L4-NN-FW by Bosch Rexroth supports EtherCAT connectivity, includes a multi-encoder interface with EnDat and Hiperface compatibility, and features safety level L4 with Safe Torque Off and Safe Brake Control. Its IP20-rated design with internal air cooling suits automated assembly, packaging, and robotics environments.

Warranty

1-year-warranty
Indramat USA 1 Year Warranty

Repair

product repair We offer a repair service for the HCS01.1E-W0018-A-03-E-S3-EC-NN-L4-NN-FW.
Indramat Is Trusted By
motion-industries-logo
3m-logo
IBM-logo
GexPro-logo
caterpillar-logo
nasa-logo
ford-logo
vallen-logo