R911333486 (HCS01.1E-W0005-A-03-B-ET-EC-NN-L4-AA-FW)
HCS IndraDrive Controllers
Technical Specifications
Rack Size
0
Compatible Motors
MSK, MCL, MSM, MS2N, Third-Party Vendors
Protection Category
IP20
Mounting Position
Vertical
Mounting Options
Left-Hand, Right-Hand, Back-Side
Preferred Mounting Option
Back-Side
Communication
Multi-Ethernet
Safety Module Slot
3
Safety Features
Safe Torque Off, Safe Brake Control
Brake Requirement
Safety Brake with Quiescent Current and Spring
Control Panel Compatibility
Standard
Firmware
Ordered Separately
Air Dissipation
Inside Cabinet
Maximum Output Current Rating
5 Amps
Maximum Connection Voltage
200 to 500 Volts AC (three-phase)
Frequently Asked Questions
Why is the 3×AC 200-500 V ±10 % input range useful?
The broad voltage tolerance covers European, American, and Asian mains standards (e.g. 230 V, 400 V) and allows ±10 % fluctuation without derating. It increases robustness to supply disturbances.
What role does the STO and SBC safety interface play?
The drive’s STO (Safe Torque Off) and SBC (Safe Brake Control) prevent torque generation and command brake release during fault or emergency conditions. These safety functions help meet machine safety standards.
How does the internal blower cooling benefit in tight cabinets of HCS01.1E-W0005-A-03-B-ET-EC-NN-L4-AA-FW controller?
The integrated blower of HCS01.1E-W0005-A-03-B-ET-EC-NN-L4-AA-FW controller ensures forced-air convection inside the controller enclosure, allowing compact mounting without external fans. It also maintains thermal stability up to rated current.
What is the target application domain for HCS01.1E-W0005-A-03-B-ET-EC-NN-L4-AA-FW controller?
The HCS01.1E-W0005-A-03-B-ET-EC-NN-L4-AA-FW controller is aimed at automation, handling, pick-and-place, packaging, and machine tool tasks which demand compact servo control
What diagnostics and fault reporting does this model support?
The drive includes built-in diagnostics for overcurrent, overheating, shorted motor winding, and sensor errors. It reports faults via the network interface and internal status registers.
Common Misspellings
HCS011EW0005A03BETECNNL4AAFW
HCS01 1E W0005 A 03 B ET EC NN L4 AA FW
hcs01.1e-w0003-a-02-b-et-ec-nn-l4-nn-fw
HCS1.1E-W0005-A-03-B-ET-EC-NN-L4-AA-FW
Internal Product Review
The HCS01.1E-W0005-A-03-B-ET-EC-NN-L4-AA-FW controller is manufactured by Bosch Rexroth have a stable MultiEthernet communication, STO/SBC safety support, and clean internal airflow cooling achieving IP20 protection. It reliably drives servo axes at 3 × AC 200–500 V input. Its modular firmware architecture and encoder flexibility make it a robust choice for high-precision automation.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0005-A-03-B-ET-EC-NN-L4-AA-FW.
Want to 