R911333494 (HCS01.1E-W0013-A-02-B-ET-EC-NN-L4-AA-FW)
HCS IndraDrive Controllers
Technical Specifications
Encoder Support
Multi-encoder
Operating Temperature
0-40 degree Celsius
Protection Measure
IP20
Digital Inputs
8
Probe Inputs
2
Combined I/O
1
Current Requirement
13 A
Cooling Method
Air Cooling
Motor Suitability
Specifically mechanized for compact MSM motors
Configuration
To be performed by a certified professional
Power Supply
Three-phase, 110-230 V, AC
Design
Advanced, firmware not included.
Frequently Asked Questions
What distinguishes the “B-ET” BASIC control section in HCS01.1E-W0013-A-02-B-ET-EC-NN-L4-AA-FW for networking?
The B-ET denotes the BASIC control section with Multi-Ethernet for enabling deterministic motion networking across sercos III, EtherNet/IP, PROFINET and EtherCAT topologies via one hardware option. It simplifies standardization across OEM platforms and reduces variant management in distributed architectures.
How do STO and SBC (L4 safety level) on HCS01 enhance machine risk reduction?
The STO (Safe Torque Off) removes drive torque command paths for preventing unintended motion, while SBC (Safe Brake Control) safely actuates a holding brake. It supports safe stops for vertical axes and suspended loads without external contactors to aid PL e/SIL 3 designs.
Why is the 3×AC 110…230 V ±10% mains window relevant for HCS01.1E-W0013-A-02-B-ET-EC-NN-L4-AA-FW?
This wide low-voltage three-phase range lets the controller operate globally on common plant supplies and controllers/UPS outputs. It also simplifies cabinet reuse in brownfield retrofits where 230-V class infrastructure is already installed.
Does firmware ship installed on HCS01 units, and how should teams source it?
The firmware is configured separately that is added during ordering or supplied as an additional line item so that the projects must include the correct MPx firmware in the BOM. It avoids commissioning delays and ensures feature parity across mixed-revision lines.
How does HCS01.1E-W0013-A-02-B-ET-EC-NN-L4-AA-FW integrate in multi-axis cells with DC-bus sharing and safety zoning?
The HCS01 supports IndraMotion/MLD topologies and standard fieldbuses for hierarchical control while its L4 safety allows axis-level safe stops within zones. It enables coordinated e-stops in cartoners, labelers and wafer handlers without over-tripping unaffected axes.
Common Misspellings
HCS011EW0013A02BETECNNL4AAFW
HCS01 1E W0013 A 02 B ET EC NN L4 AA FW
hcs01.1e-w0009_a-02-b-et-ec-nn-nn-nn-fw
HCS1.1E-W0013-A-02-B-ET-EC-NN-L4-AA-FW
Internal Product Review
Bosch Rexroth Indramat manufactures the HCS01.1E-W0013-A-02-B-ET-EC-NN-L4-AA-FW drive controller with integrates Multi-Ethernet BASIC control, STO+SBC safety and a multi-encoder interface. It is rated IP20 with internal air cooling and functions from a 3×AC 110–230 V input. This drive is designed for a load capacity of 13 A peak and it suits packaging, printing, assembly and semiconductor handling cells.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0013-A-02-B-ET-EC-NN-L4-AA-FW.
Want to 




