R911339644 (HCS01.1E-W0003-A-02-A-CC-EC-NN-L3-NN-FW)
HCS IndraDrive Controllers
Technical Specifications
Weight
1.30 kilograms
Insulation
10 Mohms at 500 V DC
Maximum Output Current
1.1 A
Maximum Input Current
3 A
Protection Certificate
IP20
Cooling
Ambient air
Communication Module
Sercos master
Interface
Multi encoder
Additional Interface
STO (safe torque off)
Permissible Mounting Location
G1
Power Supply
AC 110 - 230 V (10 percent tolerance)
Frequency Range
50 to 60 hertz
Use
Industrial
Frequently Asked Questions
How does the HCS01.1E-W0003-A-02-A-CC-EC-NN-L3-NN-FW manage thermal performance during operation?
It uses internal air cooling with an integrated blower to maintain temperature stability. This prevents heat buildup and ensures continuous operation in enclosed control cabinets.
How does SERCOS III communication enhance system coordination?
SERCOS III enables high-speed, deterministic data exchange between drives and controllers. This minimizes latency and improves multi-axis synchronization in automation systems.
Why is insulation resistance important for the HCS01.1E-W0003-A-02-A-CC-EC-NN-L3-NN-FW?
The high insulation resistance ensures electrical safety and prevents leakage currents. It also enhances the long-term reliability of the drive in fluctuating voltage conditions.
Can this drive controller be used with different power supply configurations?
Yes, it supports three-phase AC inputs between 110–230 V ±10%. This flexibility allows deployment across varying regional electrical standards.
How should the drive be mounted for optimal cooling efficiency?
It should be installed vertically with unobstructed airflow around the vents. This placement supports consistent air circulation from the integrated blower.
Common Misspellings
HCS011EW0003A02ACCECNNL3NNFW
HCS01 1E W0003 A 02 A CC EC NN L3 NN FW
hcs03.1e-w0150-a-05-nnbv-aa
HCS1.1E-W0003-A-02-A-CC-EC-NN-L3-NN-FW
Internal Product Review
The Bosch Rexroth HCS01.1E-W0003-A-02-A-CC-EC-NN-L3-NN-FW is a drive controller from the IndraDrive HCS series. It delivers 1.1 A output current, supports SERCOS III communication, and includes integrated air cooling with an internal blower. Its IP20-rated housing provides basic protection against solid objects.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0003-A-02-A-CC-EC-NN-L3-NN-FW.
Want to 