The R911340324 (HCS01.1E-W0013-A-02-B-ET-EC-EM-L3-NN-FW) is an HCS01 series drive controller designed by Bosch Rexroth for use in general automation, machine tool, printing, and robotics applications. This unit features a basic control section design and supports a mains voltage supply of 3 x AC 110–230 V ±10%. Key technical features include a device peak current of 13 A, air cooling via an integrated blower, IP20 protection rating, and a range of interfaces such as MultiEthernet for flexible field bus integration, a multi-encoder interface supporting IndraDyn, Hiperface, and EnDat 2.1/2.2 protocols, as well as encoder emulation capability. The Safe Torque Off (STO) safety interface is included to meet functional safety requirements. Firmware is not integrated and must be considered separately.

Technical Specifications

Safety Function
Safe Torque Off (STO)

Control Sections
BASIC Range

Firmware Use
Supported (Ordered Separately)

Multi-Encoder Interface
Yes

Supply Voltage Rating
5V and 12V

Main Connecting Voltage
Three-Phase AC Voltage (110V -230V)

Encoder Emulation Interface
Yes

Ingress Protection Rating
IP 20

Maximum Current Rating
13A.

How does MultiEthernet on HCS01.1E-W0013-A-02-B-ET-EC-EM-L3-NN-FW simplify controls integration?

The module supports sercos III, PROFINET IO, EtherNet/IP and EtherCAT in one hardware footprint for reducing variant management. It lets OEMs retarget networks without replacing the drive to streamline commissioning and lifecycle maintenance.

What is the role of the dual encoder interface in HCS01.1E-W0013-A-02-B-ET-EC-EM-L3-NN-FW?

The primary Hiperface/EnDat 2.1/2.2 input enables precise feedback from modern motors. Its separate encoder-emulation output feeds controllers needing incremental or absolute signals for simplifying retrofits and line upgrades.

How does STO on HCS01.1E-W0013-A-02-B-ET-EC-EM-L3-NN-FW support functional safety?

It removes drive torque without cutting main power for facilitating rapid stop categories while preserving control electronics. It reduces external relay complexity and helps meet ISO 13849/IEC 62061 architectures when properly validated.

How does the infeeding/feeded power-supply concept influence cabinet design for HCS01 units?

The DC-bus topologies allow energy exchange across axes and simplify mains components. Its designers can choose local infeed or use a feeded link for optimizing footprint, harmonic mitigation and braking energy handling.

What thermal and environmental considerations apply to the IP20, internal-air cooled construction?

The integrated blower manages convective heat removal within a protected control cabinet. Its IP20 expects enclosure shielding; observe clearances and ambient limits to prevent recirculation and maintain component service life.

HCS011EW0013A02BETECEML3NNFW

HCS01 1E W0013 A 02 B ET EC EM L3 NN FW

hcs01.1e-w0009-a-02-b-et-ec-nn-nn-aa-fw

HCS1.1E-W0013-A-02-B-ET-EC-EM-L3-NN-FW

Internal Product Review

The Bosch Rexroth Indramat’s HCS01.1E-W0013-A-02-B-ET-EC-EM-L3-NN-FW controller features MultiEthernet motion control with BASIC control section pairing and its encoder port emulation eases legacy migration. Its internal-air cooling and IP20 construction suit panel mounting. This drive is designed for 3-phase 110–230 V and its current rating is specified as 13 A peak to fit into packaging, printing, machine tools and robotics systems.