1-888-551-3082 | 1-919-443-0207 sales@indramat-usa.com

R911341042 (HCS01.1E-W0013-A-02-B-ET-EC-NN-S4-NN-FW)

HCS IndraDrive Controllers

  In-Stock, Ships 3-5 Days
Expedited Lead Times on Select Parts
1 Year Warranty Included
Free Ground Shipping
Expedited Lead Times on Select Parts
1 Year Warranty Included
Free Ground Shipping
The R911341042 (HCS01.1E-W0013-A-02-B-ET-EC-NN-S4-NN-FW) is a Bosch Rexroth HCS01 series drive controller with a BASIC control section design type and internal air cooling via an integrated blower. It is rated for a device peak current of 13 A and operates on three-phase AC input with a mains voltage range of 110–230 V ±10% at 50/60 Hz. The unit features MultiEthernet communication and supports IndraDyn series motor encoders, Hiperface, 1Vpp, TTL, EnDat 2.1, EnDat 2.2, and encoder emulations. The enclosure has an IP20 protection rating and the design is compact for use in applications such as mounting systems, food machines, printing, paper processing, and machine tools. Firmware is not included and must be ordered separately.

Technical Specifications

Product Type
Control Section

Input Current
13 A

Power Supply Requirement
110 – 230 V, three-phase AC

IP Rating
IP20

Voltage Tolerance
10% tolerance in the main connection voltage

Frequency Requirement
50/60 Hz

Firmware
Not included with the package

Delivery
Worldwide shipping available

Which fieldbus options does HCS01.1E-W0013-A-02-B-ET-EC-NN-S4-NN-FW expose under “MultiEthernet,” and how are they selected?

It supports software-configurable Ethernet stacks such as Sercos III, PROFINET IO, EtherNet/IP and EtherCAT within the same hardware. It eases PLC integration without swapping option cards.

How does the integrated blower (internal air cooling) influence enclosure design for HCS01.1E-W0013-A-02-B-ET-EC-NN-S4-NN-FW?

The unit circulates air through its chassis, so provide straight intake/exhaust paths and respect IP20, it is important to use a filtered cabinet for dusty lines. Its thermal spacing plus cabinet airflow modeling helps avoid recirculation hotspots.

What encoder families are compatible with the HCS01’s multi-encoder interface, and why does it matter?

Its interfaces include IndraDyn/HIPERFACE and EnDat 2.1/2.2, among others in the Cs family. It lets the reuse of existing motors/feedbacks or mix technologies during retrofits without mechanical changes.

What peak-current behavior should I expect from the 13 A rating, and how does it translate to axis sizing? (HCS01.1E-W0013-A-02-B-ET-EC-NN-S4-NN-FW)

Its 13 A peak allows short dynamic overloads, while continuous limits depend on ambient, cooling and motor pairings. It is recommended to use Rexroth sizing tools to map motion profiles to thermal models and verify duty cycles.

What enclosure and protection considerations arise from the IP20 rating? (Product code present: HCS01.1E-W0013-A-02-B-ET-EC-NN-S4-NN-FW)

The IP20 means finger-safe only. It is important to mount in a protective cabinet with environmental sealing and maintain creepage/clearance. Use EMC gaskets as required and route motor/encoder/line filters per the manual.

HCS011EW0013A02BETECNNS4NNFW

HCS01 1E W0013 A 02 B ET EC NN S4 NN FW

hcs01.1e-w0013-a-02-a-cc-ec-ec-nn-nn-fw

HCS1.1E-W0013-A-02-B-ET-EC-NN-S4-NN-FW

Internal Product Review

Bosch Rexroth produces the HCS01.1E-W0013-A-02-B-ET-EC-NN-S4-NN-FW drive controller with BASIC section, MultiEthernet and a multi-encoder front end. It uses internal blower cooling for thermal stability and its construction is in accordance with IP20 protective rating. It requires 3 phase 110–230 V supply source, with ±10% tolerance to deliver 13 A peak current. Its typical roles span in packaging, printing, labeling and material-handling cells.

Warranty

1-year-warranty
Indramat USA 1 Year Warranty

Repair

product repair We offer a repair service for the HCS01.1E-W0013-A-02-B-ET-EC-NN-S4-NN-FW.
Indramat Is Trusted By
motion-industries-logo
3m-logo
IBM-logo
GexPro-logo
caterpillar-logo
nasa-logo
ford-logo
vallen-logo