R911341795 (HCS01.1E-W0006-A-02-B-ET-EC-EM-L3-NN-FW)
HCS IndraDrive Controllers
Technical Specifications
Use
drive controller
Firmware required
Yes
Emergency stop switch functioning
required before commissioning
Safety technology
Safe Torque Off
Control cabinet use
mandatory
Shield grounding requirement
both ends over large surface area
Performance derating
when ambient operating temperature is exceeded
Vibration sine acceleration
1g between 57Hz -150Hz
Size
215 x 196 x 50 mm (H x T x B)
Mounting
direct left or right side
Component distance
at least 10mm in closed housing
Power rating
12.7W
Fuse
mandatory for overheat protection
Central power supply
not suitable
Leakage capacitance
maximum 17nF at 8kHz clock frequency
DC bus coupling
not suitable
Backup support
one-year
Relay contact
Bb in mains contactor circuit
Rated control voltage input
24V +/-20%
Output frequency
0Hz to 1600Hz
Environment effect
none
Housing
direct connection of equipment grounding conductor
Capacitors discharge time
minimum half hour after supply voltage off
Delivery
worldwide through vendors
Frequently Asked Questions
What installation style best suits HCS01.1E-W0006-A-02-B-ET-EC-EM-L3-NN-FW?
Designed for IP20 panels, it operates best in closed cabinets with regulated ventilation. This setup ensures safe and debris-free performance.
How are software options set on HCS01.1E-W0006-A-02-B-ET-EC-EM-L3-NN-FW?
Firmware packages are selected separately based on desired features and compliance requirements. Every installation remains traceable within plant records.
Why choose HCS01.1E-W0006-A-02-B-ET-EC-EM-L3-NN-FW for mixed controls?
It outputs encoder emulation signals for older controllers while supporting precise feedback for new systems. This allows gradual modernization without downtime.
How does HCS01.1E-W0006-A-02-B-ET-EC-EM-L3-NN-FW handle network timing?
MultiEthernet enables deterministic synchronization across connected drives. Coordinated motion remains steady, even during fast production cycles.
Which control section fits HCS01.1E-W0006-A-02-B-ET-EC-EM-L3-NN-FW?
The BASIC section simplifies control parameterization for technicians. It promotes standardization across installations with minimal learning time.
Common Misspellings
HCS011EW0006A02BETECEML3NNFW
HCS01 1E W0006 A 02 B ET EC EM L3 NN FW
hcs01.1e-w0005-a-03-b-et-ec-nn-l3-nn-fw
HCS1.1E-W0006-A-02-B-ET-EC-EM-L3-NN-FW
Internal Product Review
The Bosch Rexroth HCS01.1E-W0006-A-02-B-ET-EC-EM-L3-NN-FW merges modern MultiEthernet networking with encoder emulation for legacy controllers. It includes STO for safety and active cooling for reliability, enabling seamless hybrid operations.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0006-A-02-B-ET-EC-EM-L3-NN-FW.
Want to 