R911341860 (HCS01.1E-W0018-A-02-B-ET-EC-NN-S4-NN-FW)
HCS IndraDrive Controllers
Technical Specifications
Control Panel
Standard
Display
Single-line
Control Sections Support
BASIC range
Max Current
18A
Mains Connecting Voltage
Three-phase AC between 110V and 230V
Switching Frequencies
4kHz, 8kHz, 12kHz, and 16kHz
Ingress Protection Rating
IP 20
Encoder Interface
Multi-encoder
Encoder Supply Voltage
5V and 12V
Communcation module
Multi-Ethernet
Supported Ethernet Field Bus Systems
EtherCAT, EtherNet/IP, PROFINET IO, Sercos III
Frequently Asked Questions
How does the internal air cooling system affect the HCS drive controller’s performance?
The internal air cooling system maintains optimal temperature levels within the drive controller, ensuring stable performance even under demanding conditions. This cooling method helps to extend the service life of the device by preventing overheating.
What is the significance of the IP20 rating for the HCS drive controller’s protection?
The IP20 rating indicates that the drive controller is protected against solid objects larger than 12mm but lacks protection against water. It should be installed in dry environments to ensure proper functioning and prevent internal damage.
What benefits does the encoder support (IndraDyn Hiperface/EnDat 2.1/2.2) offer for precision control?
The encoder support facilitates precise motor feedback, ensuring accurate control of position, speed, and torque. This is crucial in applications that demand high precision for synchronization and optimal performance.
What should be considered when using a 3-phase AC power supply for the HCS drive controller?
The controller operates on a 3-phase AC voltage range of 110V to 230V, making it suitable for various international power grids. Care must be taken to ensure the voltage remains within the specified range to prevent electrical malfunctions or damage.
How does the lack of a dedicated safety interface affect the drive controller?
The absence of an additional safety interface means the device does not come with built-in safety functions like Safe Torque Off (STO) or Safe Brake Control (SBC). External safety measures must be added if required for high-risk or safety-critical applications.
Common Misspellings
HCS011EW0018A02BETECNNS4NNFW
HCS01 1E W0018 A 02 B ET EC NN S4 NN FW
hcs01.1e-w0013-a-02-b-et-ec-nn-s4-nn-aw
HCS1.1E-W0018-A-02-B-ET-EC-NN-S4-NN-FW
Internal Product Review
The Bosch Rexroth Indramat HCS01.1E-W0018-A-02-B-ET-EC-NN-S4-NN-FW controller is designed for compact drive conversions. It operates with a 110-230 V mains voltage and delivers a peak current of 18 A. Ideal for industrial automation and robotics, it integrates MultiEthernet communication and internal blower cooling for enhanced reliability in production environments.