R911342853 (HCS01.1E-W0018-A-02-A-CC-EC-EC-NN-NN-FW)
HCS IndraDrive Controllers
Technical Specifications
Design Code
01
Interfaces
Two Multi-Encoder
Protocol
SERCOS 3 Master Module
Use/Application
Printing Machinery
Analog Input
14-bit, +/-10V
Encoder Data Buffering
Two Options
Maximum Current Rating
18A
Communication
Ethernet
Clearance Requirements
Top and Bottom Inside Closed Housing
Operating Frequency
50Hz to 60Hz (+/-2%)
Control Section
Advanced
Overvoltage Category
III (IEC 60664-1 Specifications)
Safety Precautions
Check Voltage, Prevent Unintended Startup
Temperature during Operation
Above 60°C
Grounding Connector
Connected to Controller Housing
Shipping
International.
Frequently Asked Questions
How does SERCOS III “CC” cross-communication on HCS01.1E-W0018-A-02-A-CC-EC-EC-NN-NN-FW streamline multi-axis coordination?
It enables deterministic, Ethernet-based synchronization between drives without a central PLC for inter-axis exchange. It reduces bus latency and simplifies camming/gear functions in coordinated packaging and converting lines.
What advantages arise from the controller’s internal air cooling with integrated blower?
The integrated fan circulates cabinet air through the heat sink for maintaining thermal margins without external heat exchangers. It improves availability in compact panels if intake filtration and ambient limits match Bosch Rexroth guidelines.
Why offer dual encoder interfaces (IndraDyn Hiperface/EnDat 2.1/2.2) on this HCS01 drive?
The multi-encoder compatibility lets HCS01.1E-W0018-A-02-A-CC-EC-EC-NN-NN-FW interoperate with MSM/MSK and third-party motors for enabling absolute or incremental feedback. It eases retrofits and mixed fleets while preserving high-resolution position loops.
What does the IP20 rating imply for installation of HCS01.1E-W0018-A-02-A-CC-EC-EC-NN-NN-FW?
It requires mounting inside a protective cabinet with proper ingress protection and airflow management. It is important to maintain creepage/clearance and follow EMC wiring to meet industrial environments’ contamination and noise levels.
What is the role of the “ADVANCED” control section in HCS01.1E-W0018-A-02-A-CC-EC-EC-NN-NN-FW?
The ADVANCED section supports richer motion functions and extended interfaces compared to basic variants. It’s intended for applications needing complex profiles, cam tables and tighter loop rates on compact hardware.
Common Misspellings
HCS011EW0018A02ACCECECNNNNFW
HCS01 1E W0018 A 02 A CC EC EC NN NN FW
hcs01.1e-w0013-a-02-a-et-ec-ec-nn-nn-fw
HCS1.1E-W0018-A-02-A-CC-EC-EC-NN-NN-FW
Internal Product Review
The Bosch Rexroth Indramat’s HCS01.1E-W0018-A-02-A-CC-EC-EC-NN-NN-FW controller comes with an ADVANCED control section. It uses internal-blower air cooling and it is constructed in an IP20 rated enclosure for protection. The drive's dual encoder inputs accept IndraDyn Hiperface/EnDat 2.1/2.2. Its peak load capability is 18 A and it possess SERCOS III master to suit installation in packaging, printing and assembly/handling machines.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0018-A-02-A-CC-EC-EC-NN-NN-FW.
Want to 