R911343315 (HCS01.1E-W0009-A-02-A-CC-EC-EM-L3-NN-FW)
HCS IndraDrive Controllers
Technical Specifications
Product Type
Drive Controller
Connection to central supply
Not suitable
Braking resistor connection
Integrated/External at X9 connector
Engineering Interface
None
Analog Input Connection Cable
Stranded Wire with 0.2mm2 to 1.5mm2 cross-section
Drive type
Can operate as Servo or Secondary Drive
Master Interface
SERCOS III compliant with IEEE 802.3
Total Digital Inputs
Eight
Power Supply
Feeding-Style
Encoder cables
With D-Sub connector
Encoder Emulation
Incorporated
Digital Inputs/Outputs
Freely Configurable
Safety Functionality
Safe Torque Off
Control Panel
Available with memory
Residential Use
Inappropriate
Accessory Usage
Only as specified in documentation
Usage Purpose
Single- or Multi-axis Drive and Control Tasks
Backup Support
1 Year from Indramat USA
Application
Filling, Closing, Palletizing and Erecting Cartons
Digital Input Pulse Width
4μs for Type B style probe
Relay Contacts
Type 2 and Bb
Hot Plug Operation Support
None for standard control panel
Switching Frequencies
4kHz, 8kHz, 12kHz, 16kHz
Required Distance in Control Cabinet
At least 10mm from other devices.
Frequently Asked Questions
How does encoder emulation function as a fallback of HCS01.1E-W0009-A-02-A-CC-EC-EM-L3-NN-FW?
The encoder emulation synthesizes position feedback when a physical encoder signal is lost, allowing limited safe operation during faults.
Why is the STO interface of HCS01.1E-W0009-A-02-A-CC-EC-EM-L3-NN-FW important?
The STO provides immediate removal of motor torque to prevent unintended motion during hazards.
How does SERCOS III of HCS01.1E-W0009-A-02-A-CC-EC-EM-L3-NN-FW master capability help in multi-axis systems?
Acting as a master coordinates deterministic timing and ensures synchronized actuation across nodes, reducing jitter.
What are thermal best practices for cabinet mounts of HCS01.1E-W0009-A-02-A-CC-EC-EM-L3-NN-FW?
Ensure unobstructed airflow to/from the blower and maintain cabinet ventilation to avoid hot spots.
Which encoder types are compatible in HCS01.1E-W0009-A-02-A-CC-EC-EM-L3-NN-FW?
It supports IndraDyn Hiperface and EnDat protocols for high-resolution positional data and diagnostics.
Common Misspellings
HCS011EW0009A02ACCECEML3NNFW
HCS01 1E W0009 A 02 A CC EC EM L3 NN FW
hcs01.1e-w0008-a-03-b-et-ec-da-nn-nn-fw
HCS1.1E-W0009-A-02-A-CC-EC-EM-L3-NN-FW
Internal Product Review
Designed by Bosch Rexroth, the part number HCS01.1E-W0009-A-02-A-CC-EC-EM-L3-NN-FW is ideal among global automation industry users. The product IP20 protection rating ensures safe operation in controlled cabinet environments.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0009-A-02-A-CC-EC-EM-L3-NN-FW.
Want to 