R911345395 (HCS01.1E-W0008-A-03-B-ET-EC-DA-NN-NN-FW)
HCS IndraDrive Controllers
Technical Specifications
Type
Drive Controller
Power
Three-phase AC input
Input Voltage
200 - 500 Volts
Rated Output
8 Amps
Ambient Temperature
0 - 40 degrees Celsius
Installation Site Elevation
0 - 1000 meters
Max Temp with Derated Output
55 degrees Celsius
Max Installation Site Elevation with Derated Output
4000 meters
Weight
1.3 kilograms
Dimensions
215mm x 196mm x 50mm
Rated Insulation Resistance
10 megaohms
Capacitance Against Housing
2 x 68 nanofarads
Switching Frequencies
4 - 16 kilohertz
Cooling Method
Natural Convection
Spatial Requirements
90mm Top/Bottom and 10mm Horizontal Spacing
Housing
IP20 Rated
Optional Features
Digital/analog I/O module
Control Section Design
Basic control panel
Installer Requirements
Qualified and experienced personnel
Frequently Asked Questions
How does MultiEthernet simplify integration for HCS01.1E-W0008-A-03-B-ET-EC-DA-NN-NN-FW?
MultiEthernet on HCS01.1E-W0008-A-03-B-ET-EC-DA-NN-NN-FW allows direct Ethernet-based connections to PLCs and SCADA, removing gateway needs. That reduces wiring complexity and shortens the path from installation to first-run validation for machine builders.
Why pair HCS01.1E-W0008-A-03-B-ET-EC-DA-NN-NN-FW with BASIC control?
BASIC pairing simplifies parameter space on HCS01.1E-W0008-A-03-B-ET-EC-DA-NN-NN-FW, offering a dependable baseline for common axis tasks. This reduces commissioning time and minimizes configuration errors while preserving essential tuning options for final adjustments.
How does internal air cooling support reliability of HCS01.1E-W0008-A-03-B-ET-EC-DA-NN-NN-FW?
The blower on HCS01.1E-W0008-A-03-B-ET-EC-DA-NN-NN-FW keeps power electronics within rated temperatures during continuous operation. Good cabinet airflow design and intake filtration prevent thermal throttling and reduce the risk of temperature-related faults.
What does IP20 require when deploying HCS01.1E-W0008-A-03-B-ET-EC-DA-NN-NN-FW?
IP20 necessitates mounting HCS01.1E-W0008-A-03-B-ET-EC-DA-NN-NN-FW inside a protective cabinet in indoor settings to avoid moisture and fine dust. Where the environment is challenging, add enclosures or filters to retain warranty and reliable operation.
What advantage does HCS01.1E-W0008-A-03-B-ET-EC-DA-NN-NN-FW give machine builders under tight schedules?
Its BASIC-focused feature set, MultiEthernet connectivity and cabinet-ready packaging shorten integration and validation phases. This predictability enables quicker FATs and accelerated delivery while minimizing the need for custom engineering during handover.
Common Misspellings
HCS011EW0008A03BETECDANNNNFW
HCS01 1E W0008 A 03 B ET EC DA NN NN FW
hcs01.1e-w0006-a-02-b-et-ec-nn-l4-nn-fw
HCS1.1E-W0008-A-03-B-ET-EC-DA-NN-NN-FW
Internal Product Review
The HCS01.1E-W0008-A-03-B-ET-EC-DA-NN-NN-FW is a BASIC-paired MultiEthernet converter engineered for fast commissioning and predictable motion. Its cabinet-ready form and simplified feature set help machine builders deliver reliable axis control without deep custom tuning.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0008-A-03-B-ET-EC-DA-NN-NN-FW.
Want to 