R911345408 (HCS01.1E-W0008-A-03-B-ET-EC-CN-L4-NN-FW)
HCS IndraDrive Controllers
Technical Specifications
Multi-Encoder Interface
Yes
Communication Interface
Multi-Ethernet
Optional Communication Interface
CANopen
Safety Module Features
Safe torque off, safe brake control
Control Panel Compatibility
Standard
Firmware
Must be ordered separately
Connection Voltage
200 to 500 Volts AC
Output Current
8 Amps
IP Rating
IP20
Cabinet Spacing Requirement
Needed for heat dissipation
Frequently Asked Questions
What additional safety does HCS01.1E-W0008-A-03-B-ET-EC-CN-L4-NN-FW provide over L3 variants?
L4 includes Safe Brake Control in addition to Safe Torque Off, ensuring mechanical brakes engage when safety events occur. This dual approach secures loads that might otherwise coast despite electronic torque removal.
How does CANopen help distributed systems using HCS01.1E-W0008-A-03-B-ET-EC-CN-L4-NN-FW?
CANopen provides efficient, low-overhead device communication ideal for field-level networks with many nodes. It simplifies wiring and device addressing for modular machine architectures.
How does MultiEthernet interact with CANopen in HCS01.1E-W0008-A-03-B-ET-EC-CN-L4-NN-FW installations?
MultiEthernet handles higher-bandwidth supervisory protocols while CANopen manages local device messaging, enabling clean separation of control layers. This improves determinism and simplifies diagnostics across the automation stack.
What braking integrity does SBC deliver on HCS01.1E-W0008-A-03-B-ET-EC-CN-L4-NN-FW?
SBC commands the mechanical brake to engage during safety events, providing physical restraint beyond electronic torque removal. This is critical for heavy or suspended loads where residual energies may persist.
What maintenance considerations apply to the internal blower of HCS01.1E-W0008-A-03-B-ET-EC-CN-L4-NN-FW?
Periodic cleaning, filter checks and bearing inspections are recommended to maintain airflow and prevent overheating. Good blower maintenance preserves performance and avoids premature component stress.
Common Misspellings
HCS011EW0008A03BETECCNL4NNFW
HCS01 1E W0008 A 03 B ET EC CN L4 NN FW
hcs01.1e-w0006-a-02-b-et-ec-ep-s5-nn-fw
HCS1.1E-W0008-A-03-B-ET-EC-CN-L4-NN-FW
Internal Product Review
Bosch Rexroth's HCS01.1E-W0008-A-03-B-ET-EC-CN-L4-NN-FW adds safe brake control to CANopen-capable MultiEthernet architecture, supporting both electronic torque removal and mechanical braking. This suits machinery that requires guaranteed arrest under fault conditions and offers flexible fieldbus integration for modular automation designs.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0008-A-03-B-ET-EC-CN-L4-NN-FW.
Want to 