R911345876 (HCS01.1E-W0018-A-02-A-CC-EC-ET-L3-NN-FW)
HCS IndraDrive Controllers
Technical Specifications
Suitable For
Semiconductor industry
Function
Performance-dependent fan control
Additional Feature
Power supply unit integration
Interface
Multi-Ethernet interface
Input
Eight digital inputs
I/O Configuration
One combined I/O
Encoder Systems
Supports several types, 5V and 12V supply voltages
Operation Status
Not to be operated if damaged or defective
Air Humidity
Between 1g/m3 and 29g/m3
Transportation Temperature
Between -20°C and 70°C
Climatic Category
2K3 in accordance with IEC 721 specifications
Attachment
Used M5 x 12 screws with 5Nm tightening torque
Leakage Current
Over 3.5mA
Frequently Asked Questions
How does the STO safety interface in this HCS IndraDrive improve risk reduction during interventions?
The STO removes torque-producing energy in the power stage so the motor cannot generate rotation for meeting machine-safety practices for preventing unexpected start-up during access. It supports safe stops and maintenance workflows without fully removing mains.
Which encoder systems are supported, and why do dual encoder inputs matter for HCS01.1E-W0018-…-FW?
The controller accepts IndraDyn Hiperface and EnDat 2.1/2.2 via the multi-encoder interface. Its dual encoder capability enables primary servo feedback plus external load or linear scale feedback for higher positioning fidelity and compliance monitoring.
What industrial networks are addressed by the “ET” MultiEthernet option, and how does it aid lifecycle changes?
The ET option provides a MultiEthernet interface designed for various industrial-Ethernet ecosystems. It eases migration between controller platforms by decoupling the drive from a single fieldbus choice and preserving wiring/topologies during retrofits.
What thermal considerations follow from “air, internal” cooling via integrated blower in this IP20 device?
Its forced-air cooling demands unobstructed cabinet airflow and clearance to maintain rated current. Its housing is IP20 so place the unit in an enclosure meeting the environment’s dust ingress and pollution-degree requirements.
What commissioning software supports this product code, and how does it streamline engineering?
The IndraWorks provides planning, parameterization, commissioning and diagnostics across IndraDrive families. Its unified tooling shortens start-up, centralizes device management and simplifies firmware handling that’s ordered separately for HCS01 units.
Common Misspellings
HCS011EW0018A02ACCECETL3NNFW
HCS01 1E W0018 A 02 A CC EC ET L3 NN FW
hcs01.1e-w0013-a-02-a-et-ec-em-sb-nn-fw
HCS1.1E-W0018-A-02-A-CC-EC-ET-L3-NN-FW
Internal Product Review
The Indramat’s HCS01.1E-W0018-A-02-A-CC-EC-ET-L3-NN-FW drive controller is presented with saftey option of STO and dual-encoder (Hiperface/EnDat) feedback. It is rated for 3×AC 110–230 V ±10% and its peak load capacity is 18 A. This drive possesses SERCOS III cross-communication, MultiEthernet, IP20 rating and internally cooled design to suits different industrial systems including material handling and semiconductor tools.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0018-A-02-A-CC-EC-ET-L3-NN-FW.
Want to 