R911347575 (HCS01.1E-W0018-A-03-A-CC-EC-PB-S4-NN-FW)
HCS IndraDrive Controllers
Technical Specifications
Technology
Industrial Automation and Control
Used With
Drive Controller
Encoder Interfaces
Hiperface, 1Vpp, TTL, EnDat2.1/2.2
Maximum Installation Height
1000 MSL
Power Supply Requirement
Three-phase
Temperature Range
0-40 degree Celsius
Humidity Range
0-90% (no condensation)
Voltage Requirement
AC 200 - 500 V
Voltage Tolerance
10%
Mains Frequency Requirement
50 - 60 Hz
Current Requirement (Peak Load)
18 A
Installation Type
Cabinet
Protection Degree
IP20
Configuration Required
Yes
Availability
Global
Frequently Asked Questions
What feedback configurations are supported for encoder-driven applications using HCS01.1E-W0018-A-03-A-CC-EC-PB-S4-NN-FW?
This unit supports IndraDyn, Hiperface, and EnDat 2.1/2.2 encoder protocols. It enables precision feedback alignment for mixed encoder types in synchronous and asynchronous motor control environments.
Can this controller be deployed in lightly sealed panels with ambient air exposure?
With an IP20 protection rating, it resists accidental contact but lacks dust or liquid shielding. Installers must house it in fully enclosed, filtered control cabinets for industrial use.
How does HCS01.1E-W0018-A-03-A-CC-EC-PB-S4-NN-FW handle heat dissipation during sustained peak current cycles?
The internal blower cooling system actively circulates air to manage internal heat. It prevents thermal overload during high-duty operation in space-constrained enclosures.
How does the firmware requirement impact commissioning of this controller?
The ADVANCED control section requires firmware to be ordered separately. This allows system-specific function scaling but must be correctly matched to avoid startup issues.
Is simultaneous integration with Ethernet and legacy fieldbus topologies supported?
Yes, the controller includes both SERCOS III and PROFIBUS interfaces. This dual-interface setup supports hybrid network environments where modern and legacy systems coexist.
Common Misspellings
HCS011EW0018A03ACCECPBS4NNFW
HCS01 1E W0018 A 03 A CC EC PB S4 NN FW
hcs01.1e-w0018-a-02-a-et-ec-nn-nn-nn-fw
HCS1.1E-W0018-A-03-A-CC-EC-PB-S4-NN-FW
Internal Product Review
The HCS01.1E-W0018-A-03-A-CC-EC-PB-S4-NN-FW is a Bosch Rexroth drive controller with a peak current capacity of 18 A. It offers SERCOS III communication, PROFIBUS connectivity, IP20 protection, and an ADVANCED control section. The controller's integrated blower system ensures consistent internal air cooling for dependable performance.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0018-A-03-A-CC-EC-PB-S4-NN-FW.
Want to 