R911347695 (HCS01.1E-W0028-A-03-A-CC-EC-DA-NN-NN-FW)
HCS IndraDrive Controllers
Technical Specifications
Mounting position
G1
Controller type
Drive
Temperature range for operation
0 to +40 degrees Celsius
Temperature range for transport
-25 to +75 degrees Celsius
Compatible equipment
SERCOS master cross-communication module
Input current
10 A
Cooling system
Natural convection with additional fan
Interface 1
Multi-encoder
Dimensions
268 mm H x 196 mm D x 70 mm W
Protection requirement
From dust, chemicals, and moisture
Model input current
11.5 A
Maximum current
28 A
Maximum mounting height
1,000 MSL
Certification
IP20
Interface 2
Digital/analog extension
Power supply
Three-phase, 200 to 500 V with a 10% tolerance.
Frequently Asked Questions
Why is the 28 A peak current important for dynamic load adjustments in the HCS01.1E-W0028-A-03-A-CC-EC-DA-NN-NN-FW?
The 28 A peak current enables quick responses to changing load conditions. This ensures that the drive can handle fast load fluctuations without performance degradation.
How does the 3-phase AC voltage input (200-500 V) affect the HCS01.1E-W0028-A-03-A-CC-EC-DA-NN-NN-FW's power reliability?
The 3-phase AC input ensures consistent power delivery to the controller. This ensures the drive performs reliably even under varying electrical conditions across regions.
What role does the SERCOS III master communication interface play in system integration for the HCS01.1E-W0028-A-03-A-CC-EC-DA-NN-NN-FW?
The SERCOS III master interface supports cross-communication between devices. This ensures precise data exchange, optimizing the synchronization of controllers and drives in complex applications.
How does the 200-500 V voltage range benefit industrial deployment for the HCS01.1E-W0028-A-03-A-CC-EC-DA-NN-NN-FW?
The 200-500 V range allows the drive to be deployed in different industrial environments worldwide. This ensures compatibility with global voltage standards, enhancing deployment flexibility.
What makes the internal blower cooling method more efficient than external methods in the HCS01.1E-W0028-A-03-A-CC-EC-DA-NN-NN-FW?
The integrated internal blower system reduces external space requirements. This ensures effective cooling within the compact design, enhancing thermal management during extended operation.
Common Misspellings
HCS011EW0028A03ACCECDANNNNFW
HCS01 1E W0028 A 03 A CC EC DA NN NN FW
hcs01.1e-w0018-a-03-b-et-ec-cn-s4-nn-fw
HCS1.1E-W0028-A-03-A-CC-EC-DA-NN-NN-FW
Internal Product Review
The HCS01.1E-W0028-A-03-A-CC-EC-DA-NN-NN-FW drive controller from Bosch Rexroth offers 28 A peak current and features internal air cooling. It supports SERCOS III master communication and pairs with an advanced control section design, perfect for robotics and automation systems.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0028-A-03-A-CC-EC-DA-NN-NN-FW.
Want to 