R911372301 (HCS01.1E-W0018-A-02-A-CC-EC-CN-NN-NN-FW)
HCS IndraDrive Controllers
Technical Specifications
Discharging Time
30 minutes
Attachment
Type plate
Operating Temperature
No higher than 55 degree Celsius
Accessories
HAS09 mounting kit
Braking Resistor
0.15kW
Control Panel Fitting
HAP01.1A
Relay Type
Type 2
Compatible Motors
MSM, MCL, MSK, MS2N
Applications
Palletizing, pick-and-place, logistics
Protection Degree
IP 20
Interface
Multi-encoder for any standard encoder
Safety Technology
None
Size
215 x 50 mm
Supported Operation
Single-phase with derated performance
Encoder System Supply Voltage
Between V and 12V
Design
Economy design control section
Location of Operation
None residential area
Additional Requirement
Extra sensors and actuators
Order Delivery
Reputed freight carrier.
Frequently Asked Questions
What advantages does SERCOS III cross-communication bring to HCS01.1E-W0018-A-02-A-CC-EC-CN-NN-NN-FW motion networks?
It enables deterministic, synchronized exchange between drives and controllers with low jitter to support precise coordination of axes and diagnostics in real time. Its cross-communication reduces PLC load by allowing peer-to-peer status/data exchange over the ring.
How does the internal blower cooling influence cabinet design and lifetime for HCS01.1E-W0018-A-02-A-CC-EC-CN-NN-NN-FW?
The integrated fan routes air across heat-generating components for stabilizing temperature gradients and mitigating thermal cycling of power semiconductors. It often reduces external cooling hardware and simplifies ducting/clearances within IP20 control cabinets.
Which encoder systems are supported, and why does multi-encoder capability matter on this code?
The unit accepts IndraDyn feedback plus Hiperface and EnDat 2.1/2.2, with CANopen for additional devices. Its multi-encoder options streamline retrofits and enable optimized loop tuning across motor families and feedback resolutions.
What mains supply ranges and tolerances are permissible, and how do they affect commissioning?
It operates from 3×AC 110…230 V with ±10% tolerance to allow deployment in low-voltage three-phase environments without autotransformers. Its wider tolerance eases startup where line sag or inrush-induced dips occur.
Why is the “ADVANCED” control-section pairing significant, and what should integrators verify?
It pairs with the ADVANCED (A) control section for unlocking extended functions/interfaces beyond BASIC. It is important to verify the control section’s option cards and order firmware separately per the firmware sub-position note to enable intended features.
Common Misspellings
HCS011EW0018A02ACCECCNNNNNFW
HCS01 1E W0018 A 02 A CC EC CN NN NN FW
hcs01.1e-w0013-a-02-a-cc-ec-pb-nn-nn-fw
HCS1.1E-W0018-A-02-A-CC-EC-CN-NN-NN-FW
Internal Product Review
The Bosch Rexroth Indramat’s drive controller HCS01.1E-W0018-A-02-A-CC-EC-CN-NN-NN-FW integrates an ADVANCED control section with internal blower cooling and IP20 construction. It supports SERCOS III, CANopen and multi-encoder feedback. It features a rated peak current up to 18 A and operates from a 3×AC 110–230 V source. The unit's firmware can be ordered separately and its infeeding/feeded supply variants simplifies cabinet design.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0018-A-02-A-CC-EC-CN-NN-NN-FW.
Want to 