R911372529 (HCS01.1E-W0008-A-03-B-ET-EC-NN-S5-NN-FW)
HCS IndraDrive Controllers
Technical Specifications
Size
50 mm x 196 mm x 215 mm
Temperature Operating Range
0 to +40 degrees Celsius
Blower/Fan Setting
G1
Output Current Rating
2.7 A
Weight
1.30 kilos
Transportation Temperature Range
-25 to +75 degrees Celsius
Mains Connection Voltage
200-500 volts (10% tolerance)
Insulating Resistance
10 Mohm
Maximum Current Rating
8 A
Ethernet Connection
Multi-Ethernet
Interface 1
Multi-encoder
Interface 3
S5 Safe motion
Input Current Rating
2.5 A
IP Classification
IP 20
Air Gap
90 mm
Frequently Asked Questions
What communication protocol is integrated in the HCS01.1E-W0008-A-03-B-ET-EC-NN-S5-NN-FW?
It supports MultiEthernet, enabling high-speed, real-time communication between the drive and control systems. This standardizes motion coordination and simplifies multi-vendor network integration in modern automation environments.
How does internal air cooling affect the performance of the HCS01.1E-W0008-A-03-B-ET-EC-NN-S5-NN-FW?
The integrated blower maintains thermal stability by cooling power modules directly, preventing thermal overload during continuous operation. This design reduces maintenance frequency and prolongs component life under constant duty cycles.
What is the significance of the 8 A peak current rating in the HCS01.1E-W0008-A-03-B-ET-EC-NN-S5-NN-FW?
The 8 A peak capacity provides fast current response for rapid acceleration and torque demands. It enhances motion precision, particularly during high-load transients in packaging, material handling and assembly lines.
How does the BASIC control section simplify setup on the HCS01.1E-W0008-A-03-B-ET-EC-NN-S5-NN-FW?
The BASIC control section offers pre-configured parameter structures that minimize initial setup time. This ensures consistent configuration across multiple installations and reduces engineering overhead during system commissioning.
Why must firmware be ordered separately for the HCS01.1E-W0008-A-03-B-ET-EC-NN-S5-NN-FW?
Firmware is modular to allow application-specific customization without changing hardware. Ordering it separately enables users to match the correct feature set and safety certifications required for individual projects.
Common Misspellings
HCS011EW0008A03BETECNNS5NNFW
HCS01 1E W0008 A 03 B ET EC NN S5 NN FW
hcs01.1e-w0008-a-03-a-cc-ec-nn-s5-nn-fw
HCS1.1E-W0008-A-03-B-ET-EC-NN-S5-NN-FW
Internal Product Review
The Indramat's HCS01.1E-W0008-A-03-B-ET-EC-NN-S5-NN-FW combines MultiEthernet communication with blower-assisted cooling for sustained performance under continuous duty. With 8 A peak current capacity, it provides efficient torque response in compact enclosures optimized for industrial automation and servo-controlled systems.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0008-A-03-B-ET-EC-NN-S5-NN-FW.
Want to 