R911374271 (HCS01.1E-W0008-A-03-B-ET-EC-EP-NN-NN-FW)
HCS IndraDrive Controllers
Technical Specifications
Power Supply
Feeding Type
Control Section
Basic
Maximum Current Output
8 Amps
Input Voltage Range
200 to 500 Volts AC (Three-Phase)
Cooling
Forced Ventilation
Volumetric Cooling Capacity
56 m3/h
Cool Inlet
Located at Bottom of Unit
Cool Outlet
Located at Top of Unit
Communication
Integrated Multi-Ethernet
Safety Module
Vacant Slot
Control Panel
Standard
Firmware
Depends on Installed Firmware
User Requirement
Only Qualified Personnel Should Handle and Operate
Frequently Asked Questions
How does the HCS01.1E-W0008-A-03-B-ET-EC-EP-L4-NN-FW integrate into plant networks?
It uses MultiEthernet to interface directly with a variety of Ethernet-based controllers and supervisory systems, reducing protocol conversion. Proper network planning such as VLAN segregation and QoS helps prioritize motion traffic and keep latency low.
What are best practices for ventilation when installing HCS01.1E-W0008-A-03-B-ET-EC-EP-L4-NN-FW?
Provide filtered cabinet intake and ensure the blower’s airflow path is unobstructed; allow clearance for service access. Regularly inspect and clean inlet filters and the blower to prevent heat buildup and preserve consistent thermal performance.
What does IP20 imply about the operating environment of HCS01.1E-W0008-A-03-B-ET-EC-EP-L4-NN-FW?
IP20 is intended for indoor, cabinet-protected environments and does not guard against moisture or very fine particles. For dusty or wet production areas, mount the drive in a sealed enclosure or add environmental protection to the cabinet.
What should teams document when deploying HCS01.1E-W0008-A-03-B-ET-EC-EP-L4-NN-FW?
Record firmware versions, parameter baselines, safety wiring diagrams and functional test results for STO and SBC. Thorough documentation simplifies future updates, audits and troubleshooting while maintaining traceability for safety activities.
What commissioning checks validate HCS01.1E-W0008-A-03-B-ET-EC-EP-L4-NN-FW performance?
Verify encoder feedback, brake actuation timing, thermal behavior under load and network determinism. Capture baseline parameters and test results to support repeatable deployments.
Common Misspellings
HCS011EW0008A03BETECEPNNNNFW
HCS01 1E W0008 A 03 B ET EC EP NN NN FW
hcs01.1e-w0008-a-03-a-cc-ec-da-nn-nn-fw
HCS1.1E-W0008-A-03-B-ET-EC-EP-NN-NN-FW
Internal Product Review
Bosch Rexroth's HCS01.1E-W0008-A-03-B-ET-EC-EP-L4-NN-FW emphasises dual-layer stopping via electronic torque cut and brake control while keeping compact cabinet-friendly dimensions. It is aimed at systems where minimal panel real estate are critical requirements for safe operation.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0008-A-03-B-ET-EC-EP-NN-NN-FW.
Want to 