1-888-551-3082 | 1-919-443-0207 | sales@indramat-usa.com

R911375895 (HCS01.1E-W0003-A-02-A-CC-EC-EM-NN-NN-FW)

HCS IndraDrive Controllers

  Call for Quote
Expedited Lead Times on Select Parts
1 Year Warranty Included
Free Ground Shipping
Expedited Lead Times on Select Parts
1 Year Warranty Included
Free Ground Shipping
The R911375895 (HCS01.1E-W0003-A-02-A-CC-EC-EM-NN-NN-FW) is a Bosch Rexroth HCS01 series drive controller designed for industrial automation tasks including assembly, semiconductor manufacturing, printing, and palletizing. It provides control of torque, speed, and position when used with compatible motors such as MSM and potentially MSK types. The unit features an internal air cooling system, an integrated control panel for configuration and monitoring, and supports SERCOS III master cross communication with Multi-Ethernet capability. The mains voltage range is 110 to 230 V AC, with a maximum device current of 3.3 A and a rated output current of 1.1 A. The device includes encoder support via IndraDyn, Hiperface, EnDat 2.1/2.2, as well as an encoder emulation module. It is rated for installation in IP20 environments and pairs with the 'ADVANCED' control section design. Firmware for this controller is ordered separately.

Technical Specifications

Product Type
Drive Controller

Control Section
Advanced

Optimal Motor Combination
MSM Motors

Secondary Motor Compatibility
MSK Motors

Housing
IP20 Rated

Control Panel Availability
Yes

Main Connection Voltage
110 to 230 Volts AC (Three-Phase)

Maximum Output Current
3.3 Amps

Rated Output
1.1 Amps

Communication Options
SERCOS, SERCOS Master, Multi-Ethernet

Interface Type
SERCOS III

Compliancy
IEEE .802.3

Connections Available
Two RJ-45

Cable Type
Cat5e

Maximum Cable Length
100 meters

Minimum Bend Radius (Long Cables)
48.75 millimeters

Short Cable Lengths Available
0.19 meters, 0.25 meters, 0.35 meters, 0.55 meters

Minimum Bend Radius (Short Cables)
30.75 millimeters

How does the HCS01.1E-W0003-A-02-A-CC-EC-EM-NN-NN-FW manage heat during operation?

It uses internal air cooling via an integrated blower, eliminating the need for external cooling units. This simplifies installation in compact control cabinets.

What precautions should be taken when connecting 3-phase 110–230 V AC power?

Ensure balanced phase connections and proper grounding to prevent voltage imbalance. Overvoltage beyond ±10% can trigger protective shutdowns.

How does encoder emulation benefit system integration?

Encoder emulation allows the drive to output simulated encoder signals to other devices. This simplifies synchronization with legacy controllers or feedback loops.

How does the ADVANCED control section design impact functionality?

The ADVANCED design supports extended communication and control features. It allows higher-level diagnostics and multi-axis coordination.

Can the HCS01.1E-W0003-A-02-A-CC-EC-EM-NN-NN-FW be used with existing IndraDyn motors?

Yes, it supports IndraDyn encoders with Hiperface and EnDat 2.1/2.2 protocols. This allows seamless integration with compatible Rexroth servo motors.

HCS011EW0003A02ACCECEMNNNNFW

HCS01 1E W0003 A 02 A CC EC EM NN NN FW

hcs03.1e-w0100-a-05-npbv

HCS1.1E-W0003-A-02-A-CC-EC-EM-NN-NN-FW

Internal Product Review

The HCS01.1E-W0003-A-02-A-CC-EC-EM-NN-NN-FW is a compact IndraDrive Controller from the Bosch Rexroth Indramat HCS01 line. It operates on 3 x AC 110–230 V ±10%, features internal air cooling, and includes SERCOS III master communication with ADVANCED control design. It is commonly used in automation systems, robotics, and packaging machinery.

Warranty

1-year-warranty
Indramat USA 1 Year Warranty

Repair

product repair We offer a repair service for the HCS01.1E-W0003-A-02-A-CC-EC-EM-NN-NN-FW.
Indramat Is Trusted By
motion-industries-logo
3m-logo
IBM-logo
GexPro-logo
caterpillar-logo
nasa-logo
ford-logo
vallen-logo