R911378038 (HCS01.1E-W0008-A-03-B-ET-EC-EP-S4-NN-FW)
HCS IndraDrive Controllers
Technical Specifications
Type
HCS Drive Controller
AC Input
200-500 Volts AC
Peak Current Output
8 Amps
Weight
1.3 kilograms
Dimensions
215 mm (height) x 196 mm (depth) x 50 mm (width)
Insulation Resistance
10 megaohms at 500 Volts DC
Capacitance Against Housing
2 x 68 nanofarads
Housing
IP20 rated
Mounting
Cabinet, Backside, Left-hand, Right-hand
Cooling
Forced air, Inlet at the bottom, Outlet at the top
Ambient Temperature
0-40 degrees Celsius (for nominal data operation)
Control Panel
Standard
Firmware
Ordered Separately
Integrated Features
Multi-Ethernet, Multi-encoder interface
Personnel Requirements
Professionally trained and qualified.
Frequently Asked Questions
What encoder support does HCS01.1E-W0008-A-03-B-ET-EC-EP-S4-NN-FW provide?
It supports IndraDyn Hiperface and EnDat protocols for direct high-resolution feedback, enabling precise position and speed control. These protocols facilitate tighter loops and improved repeatability in multi-axis applications.
How does the HCS01.1E-W0008-A-03-B-ET-EC-EP-S4-NN-FW perform in compact cabinet layouts?
The compact footprint plus internal blower makes it suitable for dense racks, provided cabinet ventilation is adequate. Ensure service access to encoder connectors and allow airflow paths to prevent heat accumulation.
What network connectivity does HCS01.1E-W0008-A-03-B-ET-EC-EP-S4-NN-FW use?
MultiEthernet lets the drive interface natively with Ethernet-based PLCs and supervisory systems, simplifying integration. Network segmentation and proper IP planning will maintain deterministic behavior for motion commands.
How should teams plan commissioning for HCS01.1E-W0008-A-03-B-ET-EC-EP-S4-NN-FW?
Start with baseline BASIC parameter templates, verify encoder signals and validate motion under safe, low-speed conditions before ramping. Document tuned parameters for reproducible deployments across similar machines.
What maintenance tasks preserve performance of HCS01.1E-W0008-A-03-B-ET-EC-EP-S4-NN-FW?
Regularly inspect the blower, clean filters, verify encoder cable integrity and log temperature trends to detect early anomalies. Proactive maintenance prevents thermal derating and signal faults that compromise motion accuracy.
Common Misspellings
HCS011EW0008A03BETECEPS4NNFW
HCS01 1E W0008 A 03 B ET EC EP S4 NN FW
hcs01.1e-w0008-a-03-a-cc-ec-ec-l3-nn-fw
HCS1.1E-W0008-A-03-B-ET-EC-EP-S4-NN-FW
Internal Product Review
HCS01.1E-W0008-A-03-B-ET-EC-EP-S4-NN-FW targets precision lines by combining Hiperface/EnDat encoder support with a compact and blower-cooled package. Thus, the design helps deliver consistent closed-loop performance inside dense control cabinets while simplifying encoder wiring and service access.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0008-A-03-B-ET-EC-EP-S4-NN-FW.
Want to 