R911378153 (HCS01.1E-W0013-A-02-B-ET-EC-NN-S5-NN-FW)
HCS IndraDrive Controllers
Technical Specifications
Product Type
Control section
Installation
Easy
Degree of Protection
IP20
Communication
Multi-Ethernet master
Power Supply
3 x AC 110– 230 V with 10% tolerance
Firmware
Not included, must be ordered separately
Digital Inputs
8 (2 probe inputs, 1 combined I/O)
Seller
Indramat USA
Radiation Resistance
Low
Frequently Asked Questions
Can HCS01.1E-W0013-A-02-B-ET-EC-NN-S5-NN-FW handle rapid load steps on compact axes?
Yes, its W0013 rating delivers a 13 A device peak to accommodate short-term torque demands during bursts or indexing. Its BASIC control section maintains loop stability while the blower manages thermal transients in cabinet environments.
What encoder interfaces are available and why do they matter for commissioning speed?
The controller evaluates multi-encoder inputs including IndraDyn HIPERFACE® and EnDat 2.1/2.2 for enabling flexible feedback selection from legacy to modern motors. Its compatibility streamlines retrofit projects and simplifies spare-part strategies when standardizing across plants.
How does MultiEthernet on HCS01.1E-W0013-A-02-B-ET-EC-NN-S5-NN-FW aid deterministic control in distributed machines?
The MultiEthernet provides time-synchronized cyclic exchange for motion and diagnostics across heterogeneous topologies for reducing gateway latency and easing PLC integration. It supports sercos III within the MultiEthernet stack for precise velocity/position loops in multi-axis cells.
How does the 3×AC 110–230 V ±10% mains range influence panel design and global deployment?
Its wide low-voltage three-phase input simplifies transformer selection and supports regions with 208/230 V infrastructure. It also enables mixed-voltage lines where auxiliary equipment shares the same feeder for easing harmonization of spares and UL/CE panel builds.
How does the integrated blower cooling method impact lifecycle and maintenance?
It removes the need for external fan kits on the drive to simplify service BOMs. Its performance-dependent fan control limits dust loading and bearing wear for extending mean-time-between-service in continuous-duty applications.
Common Misspellings
HCS011EW0013A02BETECNNS5NNFW
HCS01 1E W0013 A 02 B ET EC NN S5 NN FW
hcs01.1e-w0013-a-02-a-cc-ec-em-l3-nn-fw
HCS1.1E-W0013-A-02-B-ET-EC-NN-S5-NN-FW
Internal Product Review
The Indramat’s HCS01.1E-W0013-A-02-B-ET-EC-NN-S5-NN-FW drive is presented with integrates MultiEthernet motion control with BASIC control section and encoder evaluation (Hiperface/EnDat 2.1/2.2). It possesses IP20 housing, internal-air blower and it functions from a 3×AC 110–230 V input to deliver 13 A peak current for agile axes. Its firmware is supplied separately and it serves in automation and semiconductor handling systems.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0013-A-02-B-ET-EC-NN-S5-NN-FW.
Want to 