R911379535 (HCS01.1E-W0005-A-03-B-ET-EC-EC-S4-NN-FW)
HCS IndraDrive Controllers
Technical Specifications
Product
Bosch Rexroth HCS01 drive system
Compact construction
Yes
Ethernet-based communications
Yes
Multi-protocol support
Yes
Multi-encoder interface
Yes
Integrated safety technology
Optional
System used to operate
IndraDyn motors and third-party motors
Control units
BASIC UNIVERSAL
Communication interface
Multi-Ethernet interface
Protocols supported
SERCOS III, PROFINET IO, EtherNet/IP, EtherCat
Maximum current
5A
Operating voltage
Three-phase AC, 200V to 500V
Heat elimination
Internal air cooling within control cabinet
Control panel
Standard, single-line display
Mount type
Control cabinet
Protection rating
IP 20
Frequently Asked Questions
How is torque ripple or jitter constrained using this HCS01.1E-W0005-A-03-B-ET-EC-EC-S4-NN-FW controller?
The dual encoder feedback and real-time MultiEthernet communication of HCS01.1E-W0005-A-03-B-ET-EC-EC-S4-NN-FW controller allow high-frequency control loops. In HCS01.1E-W0005, this helps reduce position error and torque fluctuation in dynamic motion profiles.
What is the significance of “Design Version 1”?
Design Version 1 indicates the first hardware revision, which pins out features, tolerances and constraints. Users must ensure peripherals or firmware are compatible with Version 1 hardware.
What is the role of firmware being ordered separately?
Firmware is modular so you can load only the required motion profile or network stack. The HCS01.1E-W0005 allows flexible firmware selection to adapt functionality to application needs.
Why is MultiEthernet used instead of standard Ethernet?
MultiEthernet supports deterministic real-time communication protocols (e.g. EtherCAT, Profinet). It’s critical for synchronization and low-latency control in systems using HCS01.1E-W0005.
How does the integrated blower cooling benefit operation?
The integrated blower ensures consistent airflow across internal power components, helping dissipate heat more effectively. It reduces hotspots inside the HCS01.1E-W0005-A-03-B-ET-EC-EC-S4-NN-FW controller, improving reliability under load.
Common Misspellings
HCS011EW0005A03BETECECS4NNFW
HCS01 1E W0005 A 03 B ET EC EC S4 NN FW
hcs01.1e-w0003-a-02-b-et-ec-ec-nn-aa-fw
HCS1.1E-W0005-A-03-B-ET-EC-EC-S4-NN-FW
Internal Product Review
The HCS01.1E-W0005-A-03-B-ET-EC-EC-S4-NN-FW drive controller offers 5 A peak current, dual IndraDyn encoder ports, and internal air cooling. Its MultiEthernet interface and IP20 protection enable precise speed, torque, and position control and is ideal for robotics, conveyors, and packaging machines.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0005-A-03-B-ET-EC-EC-S4-NN-FW.
Want to 