R911379677 (HCS01.1E-W0013-A-02-B-ET-EC-EP-NN-NN-FW)
HCS IndraDrive Controllers
Technical Specifications
Rexroth Indramat Product
Industrial Converter
Noise Generation
Low
Environmental Impact
Minimal
Material Protection
High Degree
Protection Class
IP54
Communication Interface
Multi-Ethernet
Encoder Interface
MSM, SSI, C, and MS2M
Temperature Regulation
Forced Ventilation
Integration
Servo System Integration
Input Current
13 Amperes
Mains Connecting Voltage
110-230 Volts
Grounding Requirement
Yes
Frequently Asked Questions
What encoder options are usable on the HCS01.1E-W0013-A-02-B-ET-EC-EP-NN-NN-FW and why do they matter?
Its multi-encoder front end reads IndraDyn HIPERFACE and EnDat 2.1/2.2, among others for enabling precise commutation and diagnostics with various motor families. Its flexibility eases retrofits and multi-axis builds using mixed rotary or linear feedbacks.
How does the internal air-cooling (integrated blower) influence cabinet design for HCS01.1E-W0013-A-02-B-ET-EC-EP-NN-NN-FW?
The integrated fan manages thermal load to IP20 to allow tighter panel layouts and predictable temperature rise without external heat sinks. Its designers still provision airflow paths and derating considerations for ambient and altitude.
Why is the BASIC control section (“B”) pairing significant on HCS01.1E-W0013-A-02-B-ET-EC-EP-NN-NN-FW?
The BASIC defines the communications and I/O feature set for aligning MultiEthernet with standard diagnostics and operator-panel functions. It streamlines selection for single-axis controllers where advanced safety or master functions aren’t required.
How do “infeeding/feeded” power options impact multi-axis DC-bus planning on this code?
The controller can consume from or be supplied by a shared DC-bus for enabling energy sharing and braking strategies. It supports compact multi-axis groups where regenerative modules or mains supplies are centralized.
For EtherNet/IP or EtherCAT plants, how is HCS01 series (including HCS01.1E-W0013-A-02-B-ET-EC-EP-NN-NN-FW) typically integrated?
The HCS01 drives are commonly configured as SoE/EtherCAT or mapped to Ethernet/IP objects using Rexroth engineering tools. Its proper device profiles, EDS/ESI files and synchronization settings ensure smooth PLC interoperability.
Common Misspellings
HCS011EW0013A02BETECEPNNNNFW
HCS01 1E W0013 A 02 B ET EC EP NN NN FW
hcs01.1e-w0009-a-02-e-s3-ec-ep-l4-nn-fw
HCS1.1E-W0013-A-02-B-ET-EC-EP-NN-NN-FW
Internal Product Review
The HCS01.1E-W0013-A-02-B-ET-EC-EP-NN-NN-FW drive controller from Bosch Rexroth is designed to deliver precise motor handling with MultiEthernet, IndraDyn Hiperface/EnDat feedback and IP20, blower-assisted internal cooling. It comes with BASIC control section and its firmware is supplied separately. This drive uses infeeding/feeded power topology and it is mainly used in semiconductor handling, machine tools and general automation systems.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0013-A-02-B-ET-EC-EP-NN-NN-FW.
Want to 