R911380938 (HCS01.1E-W0008-A-03-A-ET-EC-NN-S4-NN-FW)
HCS IndraDrive Controllers
Technical Specifications
Mounting Conditions
Control Cabinets
Ambient Temperature
0 to 40 degrees Celsius
Maximum Installation Altitude
1000 meters
Not Permitted Altitude
Over 4000 meters
Relative Humidity
5 to 95%
Absolute Humidity
1 to 29 g/m3
Cooling Method
Forced ventilation
Volumetric Capacity of Forced Cooling
11 m3/hour
Switching Frequencies
4, 8, 12 and 16 kilohertz
Input Rating
200 to 500 Volts AC
Maximum Output
8 Amps
Housing IP Rating
IP20
Frequently Asked Questions
What is the primary communication feature of HCS01.1E-W0008-A-03-A-ET-EC-NN-S4-NN-FW?
MultiEthernet is the primary communication feature, enabling the drive to connect directly with various Ethernet-based control systems. This reduces integration overhead and supports faster commissioning compared with gateway-dependent designs.
How does the output profile affect HCS01.1E-W0008-A-03-A-ET-EC-NN-S4-NN-FW performance?
Its output profile is tuned for stable torque delivery and predictable dynamic response, which benefits applications with steady acceleration demands. Predictable output reduces tuning iterations and improves repeatability on production lines.
How does integrated blower cooling help HCS01.1E-W0008-A-03-A-ET-EC-NN-S4-NN-FW operation?
The blower provides directed airflow to critical heat sources, maintaining thermal margins across continuous production cycles. Regular maintenance of airflow paths keeps thermal performance optimal and prevents overheating.
How does pairing with BASIC control section influence commissioning for HCS01.1E-W0008-A-03-A-ET-EC-NN-S4-NN-FW?
BASIC pairing streamlines parameter requirements and reduces complexity for standard applications, offering a quicker route to operational readiness while preserving necessary tuning options.
What maintenance practices prolong lifespan of HCS01.1E-W0008-A-03-A-ET-EC-NN-S4-NN-FW?
Regularly inspect the blower, clean dust from internal channels and verify encoder signal integrity. Proactive checks prevent thermal issues and signal degradation that could compromise motion accuracy.
Common Misspellings
HCS011EW0008A03AETECNNS4NNFW
HCS01 1E W0008 A 03 A ET EC NN S4 NN FW
hcs01.1e-w0006-a-02-b-et-ec-ep-l4-nn-fw
HCS1.1E-W0008-A-03-A-ET-EC-NN-S4-NN-FW
Internal Product Review
Indramat's HCS01.1E-W0008-A-03-A-ET-EC-NN-S4-NN-FW emphasizes compact performance with a tuned output profile and MultiEthernet capability. Designed for dense control cabinets, it offers efficient internal cooling and consistent encoder feedback compatibility, which makes it a top rated option.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0008-A-03-A-ET-EC-NN-S4-NN-FW.
Want to 