R911382718 (HCS01.1E-W0018-A-03-B-ET-EC-EC-SB-NN-FW)
HCS IndraDrive Controllers
Technical Specifications
Mounting
Rear Panel
Fixing Screws
M6 x 20
Tightening Torque of Screws
6Nm
Control Section
Basic
Operation
Exclusively done using plugged-on connectors
Material of Equipment Grounding Conductor
Same as outer conductors
Tightening Torque of Cable
0.5Nm to 0.8Nm
Support
Safe Motion Bus
Digital Inputs/Outputs
Complies with IEC 61131
Current Consumption for Digital Inputs
2mA to 5mA
Protection
Overload and Short-circuit
Cable Requirement for Analog Inputs
Shielded if more than 30m
Humidity
5% to 95%
Vibration Sine Acceleration
1g at 57Hz to 150Hz
Transportation Temperature
-20°C to 70°C
Applications
Labeling, Digital and Label Printing
Number of Digital Inputs
8
Analog Input Voltage
+/-10V
Communication Module
Multi-Ethernet
Cooling Method
Internal Air Circulation
Delivery
Worldwide Network Logistics Agents
Frequently Asked Questions
What are the key electrical ratings for this controller?
It operates at 3×AC 200–500 V input and delivers up to 7.6 A output current. This wide range supports global compatibility and flexible motor configurations.
How does the HCS01.1E-W0018-A-03-B-ET-EC-EC-SB-NN-FW manage voltage tolerance?
It accommodates ±10% voltage fluctuation without derating or instability. This tolerance ensures consistent drive control under variable mains conditions and industrial power networks.
What is the rated control voltage and consumption?
The control section requires 24 V ± 20% with approximately 34 W consumption. This low-power requirement simplifies auxiliary supply design and reduces total control cabinet load.
How do current and frequency parameters affect motor behavior?
The drive provides 0–1600 Hz output frequency for precise speed adjustment. This flexibility enables smooth operation with both high-speed and torque-oriented servo applications.
What is the significance of its short circuit rating?
A 42 kA rms short circuit current rating ensures durability in fault conditions. It allows reliable protection coordination with upstream circuit breakers and fuses.
Common Misspellings
HCS011EW0018A03BETECECSBNNFW
HCS01 1E W0018 A 03 B ET EC EC SB NN FW
hcs01.1e-w0018-a-02-e-s3-ec-ep-l3-nn-fw
HCS1.1E-W0018-A-03-B-ET-EC-EC-SB-NN-FW
Internal Product Review
The HCS01.1E‑W0018‑A‑03‑B‑ET‑EC‑EC‑SB‑NN‑FW by Rexroth Indramat is the drive controller that handles 3‑phase 200‑500 V AC and peaks at 18 A. It supports MultiEthernet communication, dual Hiperface/EnDat encoder interfaces, and includes a Safe Motion Bus (SB) safety function. It’s suitable for robotics, packaging, printing, CNC, and material‑handling systems.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0018-A-03-B-ET-EC-EC-SB-NN-FW.